Molecular tripods showing fluorescence enhancement upon binding to streptavidin

被引:16
作者
Kim, TW [1 ]
Yoon, HY
Park, JH
Kwon, OH
Jang, DJ
Hong, JI
机构
[1] Seoul Natl Univ, Coll Nat Sci, Dept Chem, Seoul 151747, South Korea
[2] Korea Adv Inst Sci & Technol, Ctr Mol Design & Synth, Taejon 305701, South Korea
关键词
D O I
10.1021/ol047801h
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
We introduce a new approach to biotin-streptavidin assays based on a molecular tripod which consists of biotin, a fluorophore, and a quencher. The interaction between streptavidin and molecular tripods perturbs the ground-state quencher-fluorophore dimeric conformation in the absence of streptavidin and diminishes the intrinsic self-quenching of a quencher-fluorophore pair. The emission intensity of the molecular tripods plus streptavidin is 3.5-5.2 times that of molecular tripods in the absence of streptavidin.
引用
收藏
页码:111 / 114
页数:4
相关论文
共 32 条
[1]   A NEW METAL SENSORY SYSTEM BASED ON INTRAMOLECULAR FLUORESCENCE QUENCHING ON THE IONOPHORIC CALIX[4]ARENE RING [J].
AOKI, I ;
SAKAKI, T ;
SHINKAI, S .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1992, (09) :730-732
[2]   OBSERVATION OF HOOK EFFECTS IN THE INHIBITION AND DOSE-RESPONSE CURVES OF BIOTIN ASSAYS BASED ON THE INTERACTION OF BIOTINYLATED GLUCOSE-OXIDASE WITH (STREPT)AVIDIN [J].
BARBARAKIS, MS ;
QAISI, WG ;
DAUNERT, S ;
BACHAS, LG .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :457-460
[3]   Fluorescent, sequence-selective peptide detection by synthetic small molecules [J].
Chen, CT ;
Wagner, H ;
Still, WC .
SCIENCE, 1998, 279 (5352) :851-853
[4]  
CHRISTOPOULOS TK, 1996, IMMUNOASSAY, V184
[5]   Enzyme fluorescence as a sensing tool: new perspectives in biotechnology [J].
D'Auria, S ;
Lakowicz, JR .
CURRENT OPINION IN BIOTECHNOLOGY, 2001, 12 (01) :99-104
[6]   Signaling recognition events with fluorescent sensors and switches [J].
de Silva, AP ;
Gunaratne, HQN ;
Gunnlaugsson, T ;
Huxley, AJM ;
McCoy, CP ;
Rademacher, JT ;
Rice, TE .
CHEMICAL REVIEWS, 1997, 97 (05) :1515-1566
[7]  
GROMAN EV, 1990, METHOD ENZYMOL, V184, P217
[8]   Biotin-fluorophore conjugates with poly(ethylene glycol) spacers retain intense fluorescence after binding to avidin and streptavidin [J].
Gruber, HJ ;
Marek, M ;
Schindler, H ;
Kaiser, K .
BIOCONJUGATE CHEMISTRY, 1997, 8 (04) :552-559
[9]   Accurate titration of avidin and streptavidin with biotin-fluorophore conjugates in complex, colored biofluids [J].
Gruber, HJ ;
Kada, G ;
Marek, M ;
Kaiser, K .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 1998, 1381 (02) :203-212
[10]   Anomalous fluorescence enhancement of Cy3 and Cy3.5 versus anomalous fluorescence loss of Cy5 and Cy7 upon covalent linking to IgG and noncovalent binding to avidin [J].
Gruber, HJ ;
Hahn, CD ;
Kada, G ;
Riener, CK ;
Harms, GS ;
Ahrer, W ;
Dax, TG ;
Knaus, HG .
BIOCONJUGATE CHEMISTRY, 2000, 11 (05) :696-704