Prediction of the calibration curves for the analysis of high absorbances using mode-mismatched dual-beam thermal lens spectrometry with chopped continuous wave laser excitation

被引:30
作者
Fischer, M [1 ]
Georges, J [1 ]
机构
[1] UNIV LYON 1, SCI ANALYT LAB, F-69622 VILLEURBANNE, FRANCE
关键词
thermal lens spectrometry; chopped excitation; high absorbance samples; lasers;
D O I
10.1016/0003-2670(95)00531-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermal lens spectrometry is a sensitive method especially designed for the analysis of weak absorbances. Recently, a convenient mathematical expression has been derived for steady-state and time-resolved measurements, using a mode-mismatched dual-beam optical configuration. This work discusses the validity of the theoretical predictions, over a wide range of concentrations including high absorbance solutions, when a chopped continuous wave laser is used to irradiate the sample. Depending on the chopping frequency and on the thermo-optical properties of the solvent, experimental calibration curves can differ significantly from the theoretical ones because of a cumulative effect induced by the chopped excitation beam on the sample. However, a good agreement is achieved when the chopping disc is arranged in such a way that the dark period following each irradiation period is long enough to allow the sample to relax to its initial thermal state before being excited again.
引用
收藏
页码:117 / 130
页数:14
相关论文
共 28 条
[1]   BEAM GEOMETRY OPTIMIZATION IN DUAL-BEAM THERMAL LENSING SPECTROMETRY [J].
BERTHOUD, T ;
DELORME, N ;
MAUCHIEN, P .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1216-1219
[2]   PULSED-LASER EXCITED DIFFERENTIAL PHOTOTHERMAL DEFLECTION SPECTROSCOPY [J].
BIALKOWSKI, SE ;
GU, XY ;
POSTON, PE ;
POWERS, LS .
APPLIED SPECTROSCOPY, 1992, 46 (09) :1335-1345
[3]   COMPARISON OF MODELS DESCRIBING THE THERMAL LENS EFFECT [J].
CARTER, CA ;
HARRIS, JM .
APPLIED OPTICS, 1984, 23 (03) :476-481
[4]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF CAROTENOIDS USING DUAL-BEAM CONTINUOUS-WAVE LASER THERMAL LENS DETECTION [J].
CHARTIER, A ;
GEORGES, J .
ANALYTICA CHIMICA ACTA, 1993, 284 (02) :311-316
[5]   EVALUATION OF THERMAL LENS DETECTION IN FLOW-INJECTION WITH HIGH BACKGROUND ABSORBENCY [J].
CHARTIER, A ;
FOX, CG ;
GEORGES, J .
ANALYST, 1993, 118 (02) :157-160
[6]  
Chartier A., 1993, ANAL METHOD INSTRUM, V1, P223
[7]  
DOVICHI NJ, 1987, CRIT REV ANAL CHEM, V17, P357, DOI 10.1080/10408348708085560
[8]   ANALYSIS OF THE THERMAL LENSING EFFECT FOR AN OPTICALLY THICK SAMPLE - REVISED MODEL [J].
FANG, HL ;
SWOFFORD, RL .
JOURNAL OF APPLIED PHYSICS, 1979, 50 (11) :6609-6615
[9]  
FRANKO M, 1991, J PHYS CHEM-US, V95, P65
[10]   DUAL-BEAM THERMAL LENS SPECTROPHOTOMETRY IN FLOWING SAMPLES WITH CHOPPED CONTINUOUS WAVE LASER EXCITATION [J].
GEORGES, J ;
MERMET, JM .
ANALYST, 1989, 114 (05) :541-546