Three-dimensional rotations of human three-joint fingers: an optoelectronic measurement. Preliminary results

被引:42
作者
Degeorges, R [1 ]
Parasie, J [1 ]
Mitton, D [1 ]
Imbert, N [1 ]
Goubier, JN [1 ]
Lavaste, F [1 ]
机构
[1] Ecole Natl Super Arts & Metiers, Lab Biomecan, F-75013 Paris, France
关键词
joint rotation; joint kinematics; human movement; 3D motion; adult hand;
D O I
10.1007/s00276-004-0277-4
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Longitudinal axial rotations of phalanges during flexion motions of digits have scarcely been analyzed with current anatomical or radiological methods. Recent optoelectronic systems were developed for three-dimensional (3D) kinematic analysis of human motion. These systems have the advantages of being non-invasive and non-irradiating. The current study was based on the VICON optoelectronic system. A validation of the protocol was made among a sample of volunteers for further direct clinical applications. An experimental protocol was set up with adaptations to the requirements of finger analyses ( multiple infrared markers inside small-sized capture volumes). The set-up and the protocol details are described. Kinematic studies consisted in recording the movements of the right hand of six volunteers ( free from any visible pathology). Results were displayed for the joints of each three-joint finger with calculation of 3D rotations. Metacarpophalangeal (MCP), proximal interphalangeal ( PIP) and distal interphalangeal ( DIP) flexion angles ranged from 78degrees to 118degrees, 72degrees to 119degrees and 9degrees to 66degrees respectively. Lateral angles ranged from 5degrees to 39degrees (MCP), 4degrees to 39degrees ( PIP) and 4degrees to 30degrees ( DIP). Mean longitudinal axial rotations of MCP, PIP and DIP joints ranged from 11degrees pronation to 26degrees supination. The index finger was in a global pronation position (five of the six specimens). The fourth and fifth fingers were in a global supination position in every case. The third finger was in a more variable global rotation ( pronation in four of the six specimens). An experimental protocol using an optoelectronic system ( VICON) has been developed for a kinematic analysis of three-joint finger. A global measure study should be initiated among a wider sample of adults. A database should be created with direct clinical applications. Patients' kinematic deficits could be graded either for standard movements (flexion/extension and abduction/adduction) or for longitudinal axial rotations.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 28 条
[11]   Comparison of the performance of 3D camera systems .2. [J].
Ehara, Y ;
Fujimoto, H ;
Miyazaki, S ;
Mochimaru, M ;
Tanaka, S ;
Yamamoto, S .
GAIT & POSTURE, 1997, 5 (03) :251-255
[12]   Rectifying postures reconstructed from joint angles to meet constraints [J].
Faraway, JJ ;
Zhang, XD ;
Chaffin, DB .
JOURNAL OF BIOMECHANICS, 1999, 32 (07) :733-736
[13]   Measurement of external three-dimensional interphalangeal loads applied during activities of daily living [J].
Fowler, NK ;
Nicol, AC .
CLINICAL BIOMECHANICS, 1999, 14 (09) :646-652
[14]  
GHANEM I, 1997, SPINE, V12, P1913
[15]   The motion path of the digits [J].
Gupta, A ;
Rash, GS ;
Somia, NN ;
Wachowiak, MP ;
Jones, J ;
Desoky, A .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (06) :1038-1042
[16]  
HAHN P, 1995, J HAND SURG-BRIT, V20, P571
[17]  
Holguín PH, 1999, CLIN ORTHOP RELAT R, P117
[18]   Passive axial rotation of the metacarpophalangeal joint [J].
Krishnan, J ;
Chipchase, L .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1997, 22B (02) :270-273
[19]   Analysis of voluntary finger movements during hand tasks by a motion analyzer [J].
Nakamura, M ;
Miyawaki, C ;
Matsushita, N ;
Yagi, R ;
Handa, Y .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (05) :295-303
[20]  
ORSET G, 1987, ANN CHIR MAIN, V10, P101