Perioperative Coagulation Profile in Living Liver Donors as Assessed by Rotational Thromboelastometry

被引:12
作者
Gouvea, Glauber [1 ,2 ,4 ]
Diaz, Rodrigo [1 ,2 ,4 ]
Auler, Lucio [1 ,2 ]
Toledo, Renato [1 ,2 ,5 ]
Soluri, Andre [1 ,2 ,5 ]
Haack, Alfredo G. [1 ,2 ]
de Oliveira, Mariana M. [1 ]
Vilanova, Bruno [1 ]
Machado, Virginia R. [1 ]
Martinho, Jose Manoel [3 ,6 ]
机构
[1] Bonsucesso Gen Hosp, Dept Anesthesiol, Rio De Janeiro, Brazil
[2] Bonsucesso Gen Hosp, Liver Transplantat Unit, Rio De Janeiro, Brazil
[3] Bonsucesso Gen Hosp, Dept Hepatobiliary Surg, Rio De Janeiro, Brazil
[4] Univ Fed Rio de Janeiro, Dept Anesthesiol, Rio De Janeiro, Brazil
[5] Natl Heart Inst Laranjeiras, Dept Anesthesiol, Rio De Janeiro, Brazil
[6] Univ Fed Fluminense, Dept Surg, Niteroi, RJ, Brazil
关键词
BLOOD-COAGULATION; RIGHT HEPATECTOMY; TRANSPLANTATION; HYPERCOAGULABILITY; THROMBOSIS; TESTS;
D O I
10.1002/lt.22011
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Transient postoperative coagulation abnormalities frequently occur in living liver donors, particularly after right liver resection Usually, this coagulopathy is diagnosed by alterations in conventional coagulation tests (CCTs) such as the international normalized ratio (INR) of the prothrombin time However, recent studies using other methods of coagulation monitoring have suggested that postoperative hypercoagulability may also occur in living donors. The rotational thromboelastometry (ROTEM) system is a coagulation monitor based on the viscoelastic properties of blood The use of ROTEM for perioperative coagulation monitoring in the setting of living liver donors has not been reported We evaluated the perioperative coagulation profile as assessed by ROTEM in 16 consecutive donors who underwent either right or left liver resection at our institution ROTEM analysis and CCTs were performed at the baseline (before skin incision) and on postoperative days 1 and 3 According to the CCTs, hypocoagulability was revealed in all but 1 (left liver) donor The INR was highest on postoperative day 1 [median = 1 67 (interquartile range = 1 37-1 8)] In contrast, all donors had a normal coagulation profile as assessed by the ROTEM system throughout the study period In conclusion, this study showed the disagreement between the CCTs and the ROTEM system, as no significant coagulation abnormalities could be revealed with the latter method during the study period Further studies are needed to confirm the role of the ROTEM system as a perioperative coagulation monitor in this setting and ultimately its influence on the outcome of living donors Liver Transpl 16:387392. 2010. (C) 2010 AASLD.
引用
收藏
页码:387 / 392
页数:6
相关论文
共 16 条
  • [1] Hypercoagulability after partial liver resection
    Bezeaud, Annie
    Denninger, Marie Helene
    Dondero, Federica
    Saada, Veronique
    Venisse, Laurence
    Huisse, Marie Genevieve
    Belghiti, Jacques
    Guillin, Marie Claude
    [J]. THROMBOSIS AND HAEMOSTASIS, 2007, 98 (06) : 1252 - 1256
  • [2] Thromboelastogram monitoring in the perioperative period of hepatectomy for adult living liver donation
    Cerutti, E
    Stratta, C
    Romagnoli, R
    Schellino, MM
    Skurzak, S
    Rizzetto, M
    Tamponi, G
    Salizzoni, M
    [J]. LIVER TRANSPLANTATION, 2004, 10 (02) : 289 - 294
  • [3] The changes in coagulation profile and epidural catheter safety for living liver donors: a report on 6 years of our experience
    Choi, Soo Joo
    Gwak, Mi Sook
    Ko, Justin Sang
    Kim, Gaab Soo
    Ahn, Hyun Joo
    Yang, Mikyung
    Hahm, Tae Soo
    Lee, Sang Min
    Kim, Myung Hee
    Joh, Jae Won
    [J]. LIVER TRANSPLANTATION, 2007, 13 (01) : 62 - 70
  • [4] Transfusion triggers in orthotopic liver transplantation: A comparison of the thromboelastometry analyzer, the thromboelastogram, and conventional coagulation tests
    Coakley, Margaret
    Reddy, Kalpana
    Mackie, Ian
    Mallett, Susan
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (04) : 548 - 553
  • [5] Live donor liver transplantation in adults
    Fan, Sheung Tat
    [J]. TRANSPLANTATION, 2006, 82 (06) : 723 - 732
  • [6] Live donor liver transplantation
    Florman, S
    Miller, CM
    [J]. LIVER TRANSPLANTATION, 2006, 12 (04) : 499 - 510
  • [7] The TEG® vs the ROTEM® thromboelastography/thromboelastometry systems
    Jackson, G. N. B.
    Ashpole, K. J.
    Yentis, S. M.
    [J]. ANAESTHESIA, 2009, 64 (02) : 212 - 215
  • [8] Hypercoagulability risks among adult living liver donors
    Lambing, A.
    Kuriakose, P.
    Abouljoud, M. S.
    [J]. TRANSPLANTATION PROCEEDINGS, 2006, 38 (10) : 3579 - 3581
  • [9] Multi-centre investigation on reference ranges for ROTEM thromboelastometry
    Lang, T
    Bauters, A
    Braun, SL
    Pötzsch, B
    von Pape, KW
    Kolde, HJ
    Lakner, M
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 2005, 16 (04) : 301 - 310
  • [10] Fibrinogen measurement to assess the risk of arterial thrombosis in individual patients: yes
    Meade, TW
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2005, 3 (04) : 632 - 634