Total reflection X-ray fluorescence analysis of light elements with synchrotron radiation and special X-ray tubes

被引:33
作者
Streli, C
Wobrauschek, P
Bauer, V
Kregsamer, P
Gorgl, R
Pianetta, P
Ryon, R
Pahlke, S
Fabry, L
机构
[1] STANFORD SYNCHROTRON RADIAT LAB,STANFORD,CA 94309
[2] LAWRENCE LIVERMORE NATL LAB,LIVERMORE,CA 94550
[3] WACKER SILTRON AG,D-84479 BURGHAUSEN,GERMANY
基金
奥地利科学基金会;
关键词
total reflection X-ray fluorescence analysis; energy dispersive X-ray fluorescence analysis; synchrotron radiation; light elements;
D O I
10.1016/S0584-8547(96)01663-1
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Total reflection X-ray fluorescence analysis (TXRF) of light elements, such as C, O and Al (atomic numbers 5-13) generally has poor sensitivity and detection limits due to poor excitation and low fluorescent yields. Special excitation sources are necessary to compensate for these physical limitations. Synchrotron radiation is the ideal source for TXRF due to its high intensity and wide spectral range extending into the low energy region required for light elements. For more routine use, special X-ray tubes can be constructed. Experiments have been performed at the Stanford Synchrotron Radiation Laboratory (SSRL) using beamline III-4, which is specially designed for the use of low energy photons. Light elements on Si wafers have been analyzed, leading to detection limits below 100 fg for Na, Mg and Al, which corresponds to about 10(9) atoms. A new vacuum chamber is introduced meeting the requirements of wafer handling without the risk of contamination and offering the possibility of scanning a certain area of the wafer, Boron was detected on a wafer with 10(14) atoms cm(-2) implanted in the surface layer. A special windowless X-ray tube with Mo, Al and Si as anode materials was also tested. With the optimization of anode geometry, beam path and excitation conditions, a detection limit of 5 pg (corresponds to 10(11) atoms) for Al was achieved. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:861 / 872
页数:12
相关论文
共 17 条
[1]  
ARAI T, 1994, 5 TXRF WORKSH TSUK
[2]  
FABRY L, 1996, 6 C TXRF REL METH EI
[3]  
FABRY L, 1996, IEEE T SEMICONDUCT M, V9, P1
[4]  
*LAWR BERK LAB, 1986, PUB490 LBL
[5]  
MADDEN MC, 1993, MATER RES SOC SYMP P, V307, P125, DOI 10.1557/PROC-307-125
[6]  
NEUMANN C, 1991, SPECTROCHIM ACTA B, V46, P1369, DOI 10.1016/0584-8547(91)80186-7
[7]   SYNCHROTRON-BASED X-RAY-LITHOGRAPHY AT STANFORD-UNIVERSITY [J].
PAN, L ;
KING, PL ;
PIANETTA, P ;
SELIGSON, D ;
BARBEE, TW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3) :287-292
[8]   APPLICATIONS OF MULTILAYERS TO SYNCHROTRON RADIATION [J].
PIANETTA, P ;
BARBEE, TW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3) :441-446
[9]  
*QXAS, 1993, IAEA VERS
[10]  
ROBINSON JW, 1979, HDB SPECTROSCOPY, V1