High-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry for the determination of flocoumafen and brodifacoum in whole blood

被引:26
作者
Jin, Mi-cong [1 ]
OuYang, Xiao-kun
Chen, Xiao-hong
机构
[1] Ningbo Municipal Ctr Dis Control & Prevent, Ningbo 315010, Peoples R China
[2] Zhejiang Univ, Dept Chem & Biochem Engn, Hangzhou 310027, Peoples R China
关键词
flocoumafen; brodifacoum; blood; HPLC-MS-MS; MRM;
D O I
10.1002/jat.1179
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 [卫生毒理学];
摘要
A high-performance liquid chromatographic-tandem mass spectrometric (HPLC-MS-MS) assay was developed and validated to determine quantitatively flocoumafen and brodifacoum in whole blood using warfarin as an internal standard (IS). Liquid-liquid extraction, using ethyl acetate, was used to isolate flocoumafen, brodifacoum and the IS from the biological matrix. Detection was performed on a mass spectrometer by negative electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The calibration curves were linear (r(2) > 0.998) in the concentration range of 0.1-100.0 ng ml(-1) with a lower limit of quantification of 0.05 ng ml(-1) for flocoumafen, and 0.1 ng ml(-1) for brodifacoum in whole blood. Intra-day and inter-day relative standard deviations (RSDs) were less than 8.0% and 10.8%, respectively. Recoveries of flocoumafen and brodifacoum ranged from 78.0% to 83.7%. This assay can be used to determine trace flocoumafen and brodifacoum in whole blood to investigate suspected poisoning of human and animals. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 12 条
[1]
Concentrations of parabens in human breast tumours [J].
Darbre, PD ;
Aljarrah, A ;
Miller, WR ;
Coldham, NG ;
Sauer, MJ ;
Pope, GS .
JOURNAL OF APPLIED TOXICOLOGY, 2004, 24 (01) :5-13
[2]
EUGENIE AP, 1995, J ANAL TOXICOL, V19, P557
[3]
Reversed-phase HPLC determination of eight anticoagulant rodenticides in animal liver [J].
Fauconnet, V ;
Pouliquen, H ;
Pinault, L .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (07) :548-553
[4]
A method for simultaneous determination of five anticoagulant rodenticides in whole blood by high-performance liquid chromatography [J].
Guan, F ;
Ishii, A ;
Seno, H ;
Watanabe, K ;
Kumazawa, T ;
Suzuki, O .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (01) :179-185
[5]
GUAN FY, 1995, CHINESE J ANAL CHEM, V23, P159
[6]
HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC STRATEGIES FOR THE DETERMINATION AND CONFIRMATION OF ANTICOAGULANT RODENTICIDE RESIDUES IN ANIMAL-TISSUES [J].
HUNTER, K .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (02) :255-272
[7]
Rapid quantification and characterization of soyasaponins by high-performance liquid chromatography coupled with electrospray mass spectrometry [J].
Jin, MC ;
Yang, YW ;
Su, BG ;
Ren, QL .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1108 (01) :31-37
[8]
LAWRENCE JF, 1991, J ANAL TOXICOL, V15, P126
[9]
Progress of liquid chromatography-mass spectrometry in clinical and forensic toxicology [J].
Marquet, P .
THERAPEUTIC DRUG MONITORING, 2002, 24 (02) :255-276
[10]
Advances in analytical toxicology: the current role of liquid chromatography-mass spectrometry in drug quantification in blood and oral fluid [J].
Maurer, HH .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (01) :110-118