A comparison of three Ni-Ti rotary instruments in apical transportation

被引:62
作者
Javaheri, Homan Hossein [1 ]
Javaheri, Ghasem Hossein [1 ]
机构
[1] Shahid Beheshti Univ, Dept Endodont, Dent Res Ctr, Tehran 19839, Iran
关键词
apical transportation; nickel-titanium rotary insruments;
D O I
10.1016/j.joen.2006.05.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare apical transportation and changes in canal curvature of three nickel-titanium (Ni-Ti) rotary instruments: Hero 642, RaCe, and ProTaper. Mesiobuccal canals of 60 maxillary first molars (with angles of curvature between 25 degrees and 35 degrees) were prepared with a torque-control, low-speed engine. Canals were prepared using the crown-down technique to the size of #30. Using a radiographic platform, reproducible preinstrumentation and postinstrumentation radiographs were taken. A computer analysis allowed magnification and superimposition of the images. The central axes of initial and final instruments were radiographically superimposed to measure transportation at 1 mm from WL. Data were analyzed using repeated-measures ANOVA. A statistically significant difference in apical transportation was found in ProTaper group. The results suggest that ProTaper file system be implemented in combination with other less tapered more flexible systems, like RaCe, in preparing curved canals.
引用
收藏
页码:284 / 286
页数:3
相关论文
共 27 条
[1]   A RADIOGRAPHIC COMPARISON OF 2 ROOT-CANAL INSTRUMENTATION TECHNIQUES [J].
BACKMAN, CA ;
OSWALD, RJ ;
PITTS, DL .
JOURNAL OF ENDODONTICS, 1992, 18 (01) :19-24
[2]   Progressive versus constant tapered shaft design using NiTi rotary instruments [J].
Bergmans, L ;
Van Cleynenbreugel, J ;
Beullens, M ;
Wevers, M ;
Van Meerbeek, B ;
Lambrechts, P .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (04) :288-295
[3]   A METHODOLOGY FOR EVALUATION OF ROOT-CANAL INSTRUMENTATION [J].
BRAMANTE, CM ;
BERBERT, A ;
BORGES, RP .
JOURNAL OF ENDODONTICS, 1987, 13 (05) :243-245
[4]  
Bryant ST, 1998, INT ENDOD J, V31, P275
[5]   Comparing apical preparations of root canals shaped by nickel-titanium rotary instruments and nickel-titanium hand instruments [J].
Deplazes, P ;
Peters, O ;
Barbakow, F .
JOURNAL OF ENDODONTICS, 2001, 27 (03) :196-202
[6]   Apical extrusion of debris and irrigants using two hand and three engine-driven instrumentation techniques [J].
Ferraz, CCR ;
Gomes, NV ;
Gomes, BPFA ;
Zaia, AA ;
Teixeira, FB ;
Souza, FJ .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (05) :354-358
[7]   Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography [J].
Gambill, JM ;
Alder, M ;
delRio, CE .
JOURNAL OF ENDODONTICS, 1996, 22 (07) :369-375
[8]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[9]   COMPARISON OF ROOT-CANAL PREPARATION USING DIFFERENT AUTOMATED DEVICES AND HAND INSTRUMENTATION [J].
HULSMANN, M ;
STRYGA, F .
JOURNAL OF ENDODONTICS, 1993, 19 (03) :141-145
[10]   A comparison of mesial molar root canal preparations using two engine-driven instruments and the balanced-force technique [J].
Imura, N ;
Kato, AS ;
Novo, NF ;
Hata, GI ;
Uemura, M ;
Toda, T .
JOURNAL OF ENDODONTICS, 2001, 27 (10) :627-631