Pulmonary capillary blood flow by partial CO2 rebreathing:: importance of the regularity of the respiratory pattern

被引:8
作者
de Abreu, MG
Melo, MFV
Giannella-Neto, A
机构
[1] Univ Fed Rio de Janeiro, COPPE, Biomed Engn Program, BR-21945970 Rio De Janeiro, Brazil
[2] Tech Univ Dresden, Univ Clin Carl Gustav Carus, Clin Anesthesiol & Intens Care Med, Dresden, Germany
[3] Harvard Univ, Sch Med, Dept Anesthesiol, Boston, MA USA
来源
CLINICAL PHYSIOLOGY | 2000年 / 20卷 / 05期
关键词
Fick principle; Fleisch pneumotacograph; respiratory mass spectrometer; repeatability; spontaneous breathing;
D O I
10.1046/j.1365-2281.2000.00271.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The partial CO2 rebreathing technique has been shown to be a reliable non-invasive method for measurement of pulmonary capillary blood flow ((Q) over dot(c)), but experience with this technique has been limited to controlled mechanical ventilation. In this study, we evaluated this technique during spontaneous and oriented ventilation in nine subjects without known cardiopulmonary disease. Subjects underwent 10 consecutive ((Q) over dot(c)) measurements with both spontaneous and oriented ventilation. Breath-by-breath gas exchange was measured and ((Q) over dot(c)) was calculated from changes in CO2 elimination and PETCO2, which were achieved by sudden increase of the apparatus deadspace (rebreathing period). An exponential curve was fitted to the PETCO2 values in the rebreathing period in order to estimate PETCO2 at equilibrium. We found that mean ((Q) over dot(c)) values were not influenced by the ventilation pattern (P = 0.51), but that the intra-individual variability with oriented ventilation (median = 16.0%) was significantly lower than with spontaneous ventilation (median = 31.8%, P = 0.039). Accordingly, the curve fitting for rebreathing PETCO2 rise failed in 4.4% of measurements with oriented ventilation vs. 18.9% of measurements with spontaneous ventilation (P = 0.039). Our results suggest that the performance of the partial CO2 rebreathing technique is adversely affected by spontaneous ventilation and, consequently, that this method should be reserved for patients with regular respiratory patterns.
引用
收藏
页码:388 / 398
页数:11
相关论文
共 21 条
[1]  
Brewer LM, 2000, CRIT CARE MED, V28, pA75
[2]   ACCURATE MEASUREMENT OF N-2 VOLUMES DURING N-2 WASHOUT REQUIRES DYNAMIC ADJUSTMENT OF DELAY TIME [J].
BRUNNER, JX ;
WOLFF, G ;
CUMMING, G ;
LANGENSTEIN, H .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (03) :1008-1012
[3]   NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT USING PARTIAL CO2 REBREATHING [J].
CAPEK, JM ;
ROY, RJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (09) :653-661
[4]   Noninvasive cardiac output monitoring by aortic blood flow determination:: Evaluation of the Sometec Dynemo-3000 system [J].
Cariou, A ;
Monchi, M ;
Joly, LM ;
Bellenfant, F ;
Claessens, YE ;
Thébert, D ;
Brunet, F ;
Dhainaut, JF .
CRITICAL CARE MEDICINE, 1998, 26 (12) :2066-2072
[5]   DETERMINATION OF MIXED VENOUS CO2 TENSIONS BY REBREATHING [J].
COLLIER, CR .
JOURNAL OF APPLIED PHYSIOLOGY, 1956, 9 (01) :25-29
[6]   White blood cell counts and plasma C3a have synergistic predictive value in patients at risk for acute respiratory distress syndrome [J].
de Abreu, MG ;
Kirschfink, M ;
Quintel, M ;
Albrecht, DM .
CRITICAL CARE MEDICINE, 1998, 26 (06) :1040-1048
[7]   Partial carbon dioxide rebreathing: A reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow [J].
deAbreu, MG ;
Quintel, M ;
Ragaller, M ;
Albrecht, DM .
CRITICAL CARE MEDICINE, 1997, 25 (04) :675-683
[8]   DETERMINATION OF PVBARCO2 FROM THE EXPONENTIAL CO2 RISE DURING REBREATHING [J].
DEFARES, JG .
JOURNAL OF APPLIED PHYSIOLOGY, 1958, 13 (02) :159-164
[9]   A NEW METHOD FOR NON-INVASIVE BEDSIDE DETERMINATION OF PULMONARY BLOOD-FLOW [J].
GEDEON, A ;
FORSLUND, L ;
HEDENSTIERNA, G ;
ROMANO, E .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (04) :411-418
[10]  
GEDEON A, 1982, J CLIN PHYSL, V5, P49