Chemiluminescence flow sensor for the determination of vitamin B12

被引:41
作者
Qin, W
Zhang, ZJ [1 ]
Liu, HJ
机构
[1] Shaanxi Normal Univ, Dept Chem, Xian 710062, Peoples R China
[2] Nanjing Univ, Dept Chem, Nanjing 210008, Peoples R China
基金
中国国家自然科学基金;
关键词
chemiluminescence; flow sensor; vitamin B-12;
D O I
10.1016/S0003-2670(97)00546-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel chemiluminescence (CL) sensor for vitamin B-12 combined with flow-injection analysis is presented in this paper. It is based on the catalytic effect of cobalt(II), liberated from vitamin B-12 by acidification, on the CL reaction between luminol, immobilized electrostatically on an anion-exchange column, and hydrogen peroxide electrochemically generated on-line via a negatively-biased electrode from dissolved oxygen in the flow cell. The sensor responds linearly to vitamin B-12 concentration in the 1.0 x 10(-3)-10 mg l(-1) range, and the detection limit is 3.5 x 10(-4) mg l(-1) vitamin B-12. A complete analysis, including sampling and washing, could be performed in 1 min with a relative standard deviation of < 3.58. The system is stable for over 500 determinations and has been applied successfully to the determination of vitamin B-12 in pharmaceutical preparations.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 27 条
[1]   DETERMINATION OF VITAMIN-B12 AS COBALT BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING THE SOLID SAMPLING TECHNIQUE [J].
AKATSUKA, K ;
ATSUVA, I .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (02) :200-204
[2]  
Atwater JE, 1997, ANAL LETT, V30, P21
[3]  
COOPER BA, 1957, J CLIN PATHOL, V12, P153
[4]   Aerosol MALDI with a reflectron time-of-flight mass spectrometer [J].
Fei, X ;
Wei, G ;
Murray, KK .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1143-1147
[5]   IMMOBILIZED LUMINOL CHEMI-LUMINESCENCE REAGENT SYSTEM FOR HYDROGEN-PEROXIDE DETERMINATIONS IN FLOWING STREAMS [J].
HOOL, K ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1988, 60 (09) :834-837
[6]   CHEMILUMINESCENCE ANALYSIS IN FLOWING STREAMS WITH LUMINOL IMMOBILIZED ON SILICA AND CONTROLLED-PORE GLASS [J].
HOOL, K ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1987, 59 (06) :869-872
[7]   ULTRAMICRODETERMINATION OF CYANOCOBALAMIN IN ELEMENTAL DIET BY SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH VISIBLE DETECTION [J].
IWASE, H .
JOURNAL OF CHROMATOGRAPHY, 1992, 590 (02) :359-363
[8]   Quantitation of vitamin B-12 by first-derivative absorption spectroscopy [J].
Karsilayan, H .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1996, 52 (09) :1163-1168
[9]   IDENTIFICATION OF VITAMIN-B12 AND ANALOGS BY HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS AND COMPARISON WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LAMBERT, D ;
ADJALLA, C ;
FELDEN, F ;
BENHAYOUN, S ;
NICOLAS, JP ;
GUEANT, JL .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :311-315
[10]  
LI G, 1990, YAOWU FENXI ZAZHI, V10, P26