Estimates of medical device-associated adverse events from emergency departments

被引:28
作者
Hefflin, BJ
Gross, TP
Schroeder, TJ
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Rockville, MD 20850 USA
[2] US Consumer Prod Safety Commiss, Bethesda, MD USA
关键词
D O I
10.1016/j.amepre.2004.04.005
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The true public health burden of adverse events associated with medical devices is unknown. The purpose of this study, therefore, was to produce the first-ever national estimates of medical device-associated adverse events resulting in emergency department (ED) visits. Methods: From July 1999 through June 2000, reports of 10,395 medical device-associated adverse events were accumulated using the National Electronic Injury Surveillance System (NEISS), which collects information on product-related injuries from the ED records of a national stratified probability sample of hospitals. The reports were used to estimate annual total number of medical device-associated adverse events as well as number of adverse events associated with specific devices, injury diagnoses, demographic characteristics, and patient disposition status. Results: The total estimated number of adverse events was 454,383 (95% confidence interval [CI] = 371,156-537,610), involving a broad range of devices from 15 medical specialty groups. Unintentional traumatic events associated with a particular device appeared to be the most common mechanism of injury. The most prevalent types of injuries included contusions/abrasions, punctures, and lacerations; 13% of total estimated cases resulted in patient hospitalization. Adverse events occurred within healthcare facilities, and some were occupationally related, although they occurred at home more frequently than any other location (about 42%). Conclusions: The magnitude of the total estimate, which is over four times greater than the annual number of adverse event reports received by medical device-regulating surveillance systems, emphasizes medical device-associated adverse events as an under-recognized public health problem. Planned collection of more detailed NEISS data will allow for appropriate public health interventions. (C) 2004 American Journal of Preventive Medicine.
引用
收藏
页码:246 / 253
页数:8
相关论文
共 24 条
[1]   Insulin pens and acute deterioration in blood glucose control [J].
Albareda, M ;
Balmes, L ;
Wagner, A ;
Corcoy, R .
ARCHIVES OF INTERNAL MEDICINE, 1999, 159 (01) :100-100
[2]  
BRIGHT RA, 2003, PHARMACOEPIDEMIOL S1, V12, P34
[3]  
Campbell P M, 1996, J Emerg Nurs, V22, P416, DOI 10.1016/S0099-1767(96)80162-0
[4]   Foreign body aspiration following unconventional use of a metered dose inhaler [J].
Campisi, P ;
Backman, SB ;
Sweet, R .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2000, 47 (08) :796-799
[5]   Selective dysfunction of ventricular electrode-endocardial junction following DC cardioversion in a patient with a dual chamber pacemaker [J].
Das, G ;
Staffanson, DB .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (02) :364-365
[6]  
De Servi S, 1999, CATHETER CARDIO INTE, V46, P13, DOI 10.1002/(SICI)1522-726X(199901)46:1<13::AID-CCD4>3.3.CO
[7]  
2-A
[8]   Branch retinal artery occlusion from a retained left aerial catheter 21 years after operation [J].
Drummond-Webb, JJ ;
Bokesch, PM ;
Ebeid, MR ;
Murphy, DJ ;
Sarris, GE ;
Mee, RBB .
ANNALS OF THORACIC SURGERY, 1998, 65 (01) :254-255
[9]  
*ECRI, 1998, HLTH DEV, V27, P277
[10]  
Gallauresi B A, 2001, Nursing, V31, P24