Direct screening of urine for MDMA and MDA by liquid chromatography-tandem mass spectrometry

被引:31
作者
Nordgren, HK [1 ]
Beck, O [1 ]
机构
[1] Karolinska Inst, Dept Med, Div Clin Pharmacol, S-17176 Stockholm, Sweden
关键词
D O I
10.1093/jat/27.1.15
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is a limit in the number of substances detected by commercially available reagents. It is therefore important to have other, complementary techniques. Liquid chromatography-tandem mass spectrometry (LC-MS-MS) may offer one possibility. An LC-MS-MS procedure based on the detection of positive ions after atmospheric pressure chemical ionization (APCI) was developed for direct measurement of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine in urine. It was compared with Online® Amphetamines. The LC-MS-MS methodology showed improved sensitivity (100-ng/mL cutoff) and specificity with a coefficient of variation of 10%. It was compared to the immunochemical analysis using 1000 clinical patient urine samples. The positive samples were confirmed by gas chromatography-mass spectrometry. The LC-MS-MS method detected almost four times as many samples positive for MDMA compared to the immunochemical method, with no false positives and one false negative. Our study suggests that LC-MS-MS offers an alternative to immunochemical methods in drug of abuse screening.
引用
收藏
页码:15 / 19
页数:5
相关论文
共 25 条
[1]   Liquid chromatography-mass spectrometry as a routine method in forensic sciences: a proof of maturity [J].
Bogusz, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 748 (01) :3-19
[2]   DETERMINATION OF URINARY 5-HYDROXYINDOLE-3-ACETIC ACID USING SOLID-PHASE EXTRACTION AND REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
CHOU, PP ;
JAYNES, PK .
JOURNAL OF CHROMATOGRAPHY, 1985, 341 (01) :167-171
[3]  
Clauwaert KM, 2000, CLIN CHEM, V46, P1968
[4]  
Fitzgerald RL, 1999, CLIN CHEM, V45, P1224
[5]   Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection [J].
Fu, I ;
Woolf, EJ ;
Matuszewski, BK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (03) :347-357
[6]   SIMPLE AND RAPID ANALYSIS OF ATENOLOL AND METOPROLOL IN PLASMA USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HARRISON, PM ;
TONKIN, AM ;
MCLEAN, AJ .
JOURNAL OF CHROMATOGRAPHY, 1985, 339 (02) :429-433
[7]   Analysis of 3,4-methylenedioxymethamphetamine (MDMA) and its metabolites in plasma and urine by HPLC-DAD and GC-MS [J].
Helmlin, HJ ;
Bracher, K ;
Bourquin, D ;
Vonlanthen, D ;
Brenneisen, R ;
Styk, J .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1996, 20 (06) :432-440
[8]   On-line solid-phase extraction-short-column liquid chromatography combined with various tandem mass spectrometric scanning strategies for the rapid study of transformation of pesticides in surface water [J].
Hogenboom, AC ;
Niessen, WMA ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 841 (01) :33-44
[9]  
Hsieh YS, 2000, RAPID COMMUN MASS SP, V14, P1384, DOI 10.1002/1097-0231(20000815)14:15<1384::AID-RCM32>3.0.CO
[10]  
2-#