Medical applications of proton transfer reaction-mass spectrometry: ambient air monitoring and breath analysis

被引:42
作者
Lirk, P
Bodrogi, F
Rieder, J
机构
[1] Univ Innsbruck, Dept Anesthesiol & Crit Care Med, A-6020 Innsbruck, Austria
[2] Med Coll Wisconsin, Dept Anesthesiol, Milwaukee, WI 53226 USA
关键词
proton transfer reaction-mass spectrometry; PTR-MS; medicine; risk environment;
D O I
10.1016/j.ijms.2004.07.016
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The analysis of volatile organic compounds (VOC) has witnessed an enormous boost over the past decade, as this substance group has received broad attention regarding indoor air quality and disease screening. This review addresses the medical applications of proton transfer reaction-mass spectrometry (PTR-MS) in the fields of risk environment monitoring and diagnostic breath sample analysis. The major advantages of PTR-MS are its ability to perform rapid measurements as needed for the quick evaluation of screening samples, and even on-line VOC profile assessment. This may be of considerable importance in the investigation of rapidly changing air contamination patterns. Sources of contamination could be unveiled in operating theatres, post-anesthesia care units, and medical sterilization wards using PTR-MS. In the field of breath analysis, PTR-MS has been employed to investigate exhaled concentrations of isoprene, methanol, potential tumor markers, and volatile anesthetics. In conclusion, PTR-MS offers highly sensitive and rapid determinations of VOC profiles as compared to other methods of detection. PTR-MS therefore basically meets the needs of a screening method. The potential of directly mirroring serum concentrations of diverse substances in real-time makes breath analysis a highly promising field of research. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:221 / 226
页数:6
相关论文
共 44 条
[31]   Online monitoring of air quality at the postanesthetic care unit by proton-transfer-reaction mass spectrometry [J].
Rieder, J ;
Prazeller, P ;
Boehler, M ;
Lirk, P ;
Lindinger, W ;
Amann, A .
ANESTHESIA AND ANALGESIA, 2001, 92 (02) :389-392
[32]  
ROITHMEIER F, 2003, EUR J ANAESTH S, V1, P18
[33]   WORK IN OPERATING-ROOMS AND PREGNANCY OUTCOME AMONG NURSES [J].
SAURELCUBIZOLLES, MJ ;
HAYS, M ;
ESTRYNBEHAR, M .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1994, 66 (04) :235-241
[34]   Exposure of postoperative nurses to exhaled anesthetic gases [J].
Sessler, DI ;
Badgwell, JM .
ANESTHESIA AND ANALGESIA, 1998, 87 (05) :1083-1088
[35]   Pollution: just a whiff of gas? ..... [J].
Sharples, A .
PAEDIATRIC ANAESTHESIA, 2003, 13 (06) :467-472
[36]   Results of long-term experimental studies on the carcinogenicity of formaldehyde and acetaldehyde in rats [J].
Soffritti, M ;
Belpoggi, F ;
Lambertini, L ;
Lauriola, M ;
Padovani, M ;
Maltoni, C .
CARCINOGENESIS BIOASSAYS AND PROTECTING PUBLIC HEALTH: COMMEMORATING THE LIFEWORK OF CESARE MALTONI AND COLLEAGUES, 2002, 982 :87-105
[37]   EFFECT OF REGULATING CHOLESTEROL-BIOSYNTHESIS ON BREATH ISOPRENE EXCRETION IN MEN [J].
STONE, BG ;
BESSE, TJ ;
DUANE, WC ;
EVANS, CD ;
DEMASTER, EG .
LIPIDS, 1993, 28 (08) :705-708
[38]   Sevoflurane in exhaled air of operating room personnel [J].
Summer, G ;
Lirk, P ;
Hoerauf, K ;
Riccabona, U ;
Bodrogi, F ;
Raifer, H ;
Deibl, M ;
Rieder, J ;
Schobersberger, W .
ANESTHESIA AND ANALGESIA, 2003, 97 (04) :1070-1073
[39]  
TAN M, 2001, BR J ANAESTH S, V1
[40]  
Taucher J, 1997, RAPID COMMUN MASS SP, V11, P1230