Comparison of slurry sampling and microwave-assisted digestion for calcium, magnesium, iron, copper and zinc determination in fish tissue samples by flame atomic absorption spectrometry

被引:29
作者
Bugallo, Raquel Alonso [1 ]
Segade, Susana Rio [1 ]
Gomez, Esperanza Fernandez [1 ]
机构
[1] Univ Vigo, Dept Quim Analit & Alimentaria, Area Quim Analit, Fac Ciencias Ourense, Orense 32004, Spain
关键词
slurry sampling; microwave-assisted digestion; calcium; magnesium; iron; copper and zinc determination; fish tissue samples; flame atomic absorption spectrometry;
D O I
10.1016/j.talanta.2006.09.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a slurry sampling method for the determination of calcium, copper, iron, magnesium and zinc in fish tissue samples by flame atomic absorption spectrometry is described. In comparison with microwave-assisted digestion, the proposed method is simple, requires short time and eliminates total sample dissolution before analysis. Suspension medium was optimized for each analyte to obtain quantitative recoveries from fish tissue samples without matrix interferences. Nevertheless, iron recoveries higher than 46% were not found. Treatment of samples slurried in nitric acid by microwave irradiation for 15-30 s at 75-285 W permitted to achieve efficient recoveries for calcium, iron, magnesium and zinc. Further improvement in the matrix effects for iron determination was accomplished. by the use of an additional step of short microwave-assisted suspension treatment. However, standard addition method was required for calcium and copper determination, being necessary hydrochloric acid as suspension medium for the last one. Although copper could not be determined in the certified reference material using microwave-assisted digestion, the accuracy of the slurry sampling method was verified for all the investigated analytes. Detection limits were 22.8 +/- 8.0, 0.884 +/- 0.092, 5.07 +/- 0.76, 35.5 +/- 0.7 and 1.17 +/- 0.04 mu g g(-1) for calcium, copper, iron, magnesium and zinc, respectively. The standard deviations obtained using slurry sampling method and microwave-assisted digestion were not significantly different, and the mean relative standard deviation of the over-all method (n = 3) of the slurry sampling method for different concentration levels was below 12%. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 65
页数:6
相关论文
共 31 条
[1]  
BARRERA PB, 2002, TALANTA, V57, P969
[2]   FLOW-INJECTION FLAME ATOMIC-ABSORPTION SPECTROMETRY FOR SLURRY ATOMIZATION - DETERMINATION OF MANGANESE, LEAD, ZINC, CALCIUM, MAGNESIUM, IRON, SODIUM AND POTASSIUM IN CEMENTS [J].
BAUTISTA, MA ;
SIRVENT, CP ;
GARCIA, IL ;
CORDOBA, MH .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (06) :359-364
[3]  
Bermejo-Barrera P, 2000, ATOM SPECTROSC, V21, P5
[4]   Acid predigestion as a slurry pretreatment for the determination of Ca, Cu, K, Mg, Na and Zn in human scalp hair by flame atomic absorption/emission spectrometry with a high-performance nebulizer [J].
Bermejo-Barrera, P ;
Moreda-Pineiro, A ;
Moreda-Pineiro, J ;
Bermejo-Barrera, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (06) :707-711
[5]   POTASSIUM DETERMINATION BY SLURRY TECHNIQUE [J].
BROWN, JH ;
VAZ, JE ;
BENZO, Z ;
VELOSA, M .
ANALYST, 1995, 120 (04) :1215-1220
[6]   Determination of lead in biological samples by use of slurry sampling electrothermal atomic absorption spectrometry [J].
Cid, BW ;
Silva, C ;
Boia, C .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) :477-483
[7]   Simultaneous determination of Cd and Pb in foodstuffs by electrothermal atomic absorption spectrometry [J].
Correia, PRM ;
Oliveira, E ;
Oliveira, PV .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :205-211
[8]   Comparison of heating extraction procedures for Al, Ca, Mg, and Mn in tea samples [J].
Costa, LM ;
Gouveia, ST ;
Nóbrega, JA .
ANALYTICAL SCIENCES, 2002, 18 (03) :313-318
[9]   Flow injection microwave-assisted dissolution of silicate rocks for magnesium determination by flame atomic absorption spectrometry [J].
DeAlmeida, MD ;
Leandro, KC ;
DaCosta, CV ;
Santelli, RE ;
DelaGuardia, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (10) :1235-1238
[10]   Development of a modified medium pressure microwave vapor-phase digestion method for difficult to digest organic samples [J].
Eilola, K ;
Perämäki, P .
ANALYST, 2003, 128 (02) :194-197