Isolation and characterization of mutated alcohol oxidases from the yeast Hansenula polymorpha with decreased affinity toward substrates and their use as selective elements of an amperometric biosensor

被引:15
作者
Dmytruk, Kostyantyn V.
Smutok, Oleh V.
Ryabova, Olena B.
Gayda, Galyna Z.
Sibirny, Volodymyr A.
Schuhmann, Wolfgang
Gonchar, Mykhailo V.
Sibirny, Andriy A.
机构
[1] NAS Ukraine, Inst Cell Biol, UA-79005 Lvov, Ukraine
[2] Rzeszow Univ, Dept Metab Engn, PL-35601 Rzeszow, Poland
[3] Ruhr Univ Bochum, D-44780 Bochum, Germany
关键词
D O I
10.1186/1472-6750-7-33
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: Accurate, rapid, and economic on-line analysis of ethanol is very desirable. However, available biosensors achieve saturation at very low ethanol concentrations and thus demand the time and labour consuming procedure of sample dilution. Results: Hansenula polymorpha (Pichia angusta) mutant strains resistant to allyl alcohol in methanol medium were selected. Such strains possessed decreased affinity of alcohol oxidase (AOX) towards methanol: the K-M values for AOX of wild type and mutant strains CA2 and CA4 are shown to be 0.62, 2.48 and 1.10 mM, respectively, whereas V-max values are increased or remain unaffected. The mutant AOX alleles from H. polymorpha mutants CA2 and CA4 were isolated and sequenced. Several point mutations in the AOX gene, mostly different between the two mutant alleles, have been identified. Mutant AOX forms were isolated and purified, and some of their biochemical properties were studied. An amperometric biosensor based on the mutated form of AOX from the strain CA2 was constructed and revealed an extended linear response to the target analytes, ethanol and formaldehyde, as compared to the sensor based on the native AOX. Conclusion: The described selection methodology opens up the possibility of isolating modified forms of AOX with further decreased affinity toward substrates without reduction of the maximal velocity of reaction. It can help in creation of improved ethanol biosensors with a prolonged linear response towards ethanol in real samples of wines, beers or fermentation liquids.
引用
收藏
页数:7
相关论文
共 19 条
  • [1] Bi-enzyme alcohol biosensors based on genetically engineered alcohol oxidase and different peroxidases
    Alpeeva, IS
    Vilkanauskyte, A
    Ngounou, B
    Csöregi, E
    Sakharov, IY
    Gonchar, M
    Schuhmann, W
    [J]. MICROCHIMICA ACTA, 2005, 152 (1-2) : 21 - 27
  • [2] [Anonymous], MULTIPLE SEQUENCE AL
  • [3] AN ENZYME ELECTRODE FOR ONLINE DETERMINATION OF ETHANOL AND METHANOL
    BELGHITH, H
    ROMETTE, JL
    THOMAS, D
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1987, 30 (09) : 1001 - 1005
  • [4] DOWIS E, 1983, QUANTITATIVE PROBLEM
  • [5] Gonchar MV, 2001, FOOD TECHNOL BIOTECH, V39, P37
  • [6] Hopkins T.R., 1987, MICROBIAL GROWTH C1, P150
  • [7] MOLECULAR-CLONING AND CHARACTERIZATION OF A GENE CODING FOR METHANOL OXIDASE IN HANSENULA-POLYMORPHA
    LEDEBOER, AM
    EDENS, L
    MAAT, J
    VISSER, C
    BOS, JW
    VERRIPS, CT
    JANOWICZ, Z
    ECKART, M
    ROGGENKAMP, R
    HOLLENBERG, CP
    [J]. NUCLEIC ACIDS RESEARCH, 1985, 13 (09) : 3063 - 3082
  • [8] Ethanol amperometric biosensor based on an alcohol oxidase graphite-polymer biocomposite
    Morales, A
    Cespedes, F
    Martinez-Fabregas, E
    Alegret, S
    [J]. ELECTROCHIMICA ACTA, 1998, 43 (23) : 3575 - 3579
  • [9] Screen-printed biosensors using different alcohol oxidases
    Patel, NG
    Meier, S
    Cammann, K
    Chemnitius, GC
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 75 (1-2) : 101 - 110
  • [10] Sambrook J., 1989, MOL CLONING LAB MANU, V2nd ed.