Cyanide ion minisensor based on methemoglobin incorporated in metal supported self-assembled bilayer lipid membranes and modified with platelet-activating factor

被引:24
作者
Siontorou, CG [1 ]
Nikolelis, DP [1 ]
机构
[1] Univ Athens, Dept Chem, Analyt Chem Lab, Athens 15771, Greece
关键词
electrochemistry; minisensor; self-assembled bilayer lipid membranes; methemoglobin; cyanide ions;
D O I
10.1016/S0003-2670(97)00510-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper reports the development of an electrochemical minisensor for the detection of cyanide ions based on methemoglobin, which is incorporated into self-assembled bilayer lipid membranes (s-BLMs) on a metal support. The presence of cyanide in solution was found to modulate the ion permeability of BLMs containing methemoglobin, when using a lipid composition containing egg phosphatidylcholine (egg PC) and semisynthetic platelet-activating factor (PAF; 1-O-alkyl-2-acetyl-sn-glyceryl-3-phosphorylcholine, AGEPC). The cyanide ion sensor exhibited good mechanical stability and longevity (routinely over 48 h) and constant sensitivity and response to a given concentration of cyanide ion in solution. Incorporation of hemoglobin or methemoglobin into s-BLMs was examined, and methemoglobin was found to provide lower (by five-fold) detection limit for cyanide ion determination. The effects of protein concentration and composition of BLMs on sensitivity of response were examined. Selectivity studies of cyanide detection were done in the presence of oxygen, carbon monoxide and dioxide. and other anions. The present cyanide ion sensor based on thin lipid film technology provides advantages of fast response times (in the order of 10 s) to alterations of cyanide ion concentration, low detection limits (ca. 4.9 nM, 0.317 mu g l(-1)), and the capability of analyzing small volumes of samples. Furthermore, a device can now simply and reliably be fabricated at low cost, and therefore can be used as a disposable sensor. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 35 条
  • [1] MOLECULAR DETERMINANTS OF CHANNEL FUNCTION
    ANDERSEN, OS
    KOEPPE, RE
    [J]. PHYSIOLOGICAL REVIEWS, 1992, 72 (04) : S89 - S158
  • [2] Kinetic and spectroscopic properties of the cyanide complexes of ferrous haemoglobins I and IV from trout blood
    Antonini, G
    Bellelli, A
    Brunori, M
    Falcioni, G
    [J]. BIOCHEMICAL JOURNAL, 1996, 314 : 533 - 540
  • [3] POTENTIOMETRIC DETERMINATION OF CHLORIDES WITH AN AIR-GAP CYANIDE SENSOR
    BARANOWSKI, R
    KUBIK, T
    [J]. TALANTA, 1993, 40 (09) : 1465 - 1471
  • [4] A NOVEL PHOTOCATALYTIC METHOD FOR DETOXIFICATION OF CYANIDE WASTES
    BHAKTA, D
    SHUKLA, SS
    CHANDRASEKHARAIAH, MS
    MARGRAVE, JL
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (03) : 625 - 626
  • [5] ENTRAPMENT OF HEMOGLOBIN INTO LIPOSOMES BY THE DEHYDRATION-REHYDRATION METHOD - VESICLE CHARACTERIZATION AND IN-VIVO BEHAVIOR
    BRANDL, M
    GREGORIADIS, G
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1994, 1196 (01): : 65 - 75
  • [6] CUMMINGS RH, 1987, CLIN CHEM, V33, P493
  • [7] COMPARATIVE-STUDIES OF THE DETERMINATION OF CYANIDE AT LOW CONCENTRATION LEVELS IN WASTE-WATERS
    DONASCIMENTO, PC
    SCHWEDT, G
    [J]. ANALYTICA CHIMICA ACTA, 1993, 283 (02) : 755 - 761
  • [8] GALYAMEDINOV GY, 1993, J ANAL CHEM MOSCOW, V48, P731
  • [9] SORPTION OF LOW-LEVELS OF CYANIDE BY GRANULAR ACTIVATED CARBON
    GUO, R
    CHAKRABARTI, CL
    SUBRAMANIAN, KS
    MA, XJ
    LU, YJ
    CHENG, JG
    PICKERING, WF
    [J]. WATER ENVIRONMENT RESEARCH, 1993, 65 (05) : 640 - 644
  • [10] DETERMINATION OF CYANIDE BY ATOMIC-ABSORPTION USING A FLOW-INJECTION CONVERSION METHOD
    HAJHUSSEIN, AT
    CHRISTIAN, GD
    RUZICKA, J
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (01) : 38 - 42