Prospective registration of human head magnetic resonance images for reproducible slice positioning using localizer images

被引:16
作者
Gedat, E [1 ]
Braun, J [1 ]
Sack, I [1 ]
Bernarding, J [1 ]
机构
[1] Charite Univ Med Berlin, Inst Med Informat, D-12200 Berlin, Germany
关键词
prospective registration; slice positioning; MR imaging; neuroimaging; cross-correlation;
D O I
10.1002/jmri.20153
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: : To facilitate assessing brain tumor growth and progression of stroke lesions by reproducible slice positioning in human head magnetic resonance (MR) images, a method for prospective registration is proposed that adjusts the image slice position without moving the patient and with no additional scans. Materials and Methods: The gradient reference frame of follow-up examinations was adjusted to achieve the same image slice positioning relative to the patient as in the previous examination. The three-dimensional geometrical transformation parameters for the gradients were determined using two-dimensional image registration of three orthogonal localizer images. The method was developed and evaluated using a phantom with arbitrarily adjustable position. Feasibility for in vivo applications was demonstrated with brain MR imaging (MRI) of healthy volunteers. Results: Standard retrospective registration was used for assessing the quality of the method. The accuracy of the realignment was 0.0 mm +/- 1.2 mm and -0.2degrees +/- 0.9degrees (mean +/- SD) in phantom experiments. In 10 examinations of volunteers, misalignments up to 49.2 mm and 21degrees were corrected. The accuracy of the realignment after prospective registration was 0.1 mm +/- 1.5 mm and 0.2degrees +/- 1.5degrees. Conclusion: Image-based prospective registration using localizer images of the pre- and postexaminations is a robust method for reproducible slice positioning.
引用
收藏
页码:581 / 587
页数:7
相关论文
共 24 条
  • [11] Maintz J B, 1998, Med Image Anal, V2, P1, DOI 10.1016/S1361-8415(01)80026-8
  • [12] Mathiak K, 2001, MAGNET RESON MED, V45, P167, DOI 10.1002/1522-2594(200101)45:1<167::AID-MRM1023>3.0.CO
  • [13] 2-M
  • [14] McGee KP, 2000, MAGN RESON MED, V43, P583, DOI 10.1002/(SICI)1522-2594(200004)43:4<583::AID-MRM13>3.0.CO
  • [15] 2-B
  • [16] Analysis of interpolation effects in the reslicing of functional MR images
    Ostuni, JL
    Santha, AKS
    Mattay, VS
    Weinberger, DR
    Levin, RL
    Frank, JA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (05) : 803 - 810
  • [17] Thesen S, 2000, MAGNET RESON MED, V44, P457, DOI 10.1002/1522-2594(200009)44:3<457::AID-MRM17>3.0.CO
  • [18] 2-R
  • [19] VANDERKOUWE A, 2003, P 11 ANN M ISMRM TOR, P797
  • [20] Ward HA, 2000, MAGNET RESON MED, V43, P459, DOI 10.1002/(SICI)1522-2594(200003)43:3<459::AID-MRM19>3.0.CO