Routine intravascular ultrasound scanning guidance of coronary stenting is not associated with improved clinical outcomes

被引:13
作者
Orford, JL
Denktas, AE
Williams, BA
Fasseas, P
Willerson, JT
Berger, PB
Holmes, DR
机构
[1] Mayo Clin, Div Cardiovasc Med, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Internal Med, Rochester, MN 55905 USA
[3] Mayo Alliance Clin Trials, Rochester, MN USA
[4] Univ Texas, Hlth Sci Ctr, Dept Internal Med, Houston, TX 77225 USA
[5] Texas Heart Inst, Houston, TX 77025 USA
关键词
D O I
10.1016/j.ahj.2004.03.033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose The purpose of the current study was to determine whether there is any incremental benefit to routine intravascular ultrasound (IVUS) guidance of percutaneous coronary intervention. Methods and Results We compared the outcome of 796 patients who underwent an IVUS study (IVUS group) during the index stent procedure with 8274 patients who did not have an IVUS study (angiography group). The primary end point was the composite end point of death, myocardial infarction, or ischemia-driven target vessel revascularization within 9 months of the index stent procedure. There were statistically significant differences in multiple procedural characteristics. Most importantly, those patients who underwent an IVUS study had a larger postprocedural minimal lumen diameter and smaller postprocedural percent diameter stenosis. However, there was no significant difference between the IVUS group and the angiography group with respect to the primary end point (RR 1.10, 95% CI 0.91, 1.32) or any of the individual clinical end points. Adjustment for multiple clinical and procedural characteristics did not significantly alter these findings. Conclusions These data suggest that the routine performance of IVUS during stent placement influences the performance of the procedure, as judged by differences in procedural characteristics, but does not improve clinical outcome at 9 months.
引用
收藏
页码:501 / 506
页数:6
相关论文
共 27 条
[1]   Acute and long/term results of an intravascular ultrasound-guided percutaneous transluminal coronary angioplasty/provisional stent implantation strategy [J].
Abizaid, A ;
Pichard, AD ;
Mintz, GS ;
Abizaid, AS ;
Klutstein, MW ;
Satler, LF ;
Mehran, R ;
Leiboff, B ;
Kent, KM ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (11) :1298-1303
[2]   Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions [J].
Albiero, R ;
Rau, T ;
Schluter, M ;
DiMario, C ;
Reimers, B ;
Mathey, DG ;
Tobis, JM ;
Schofer, J ;
Colombo, A .
CIRCULATION, 1997, 96 (09) :2997-3005
[3]  
Blasini R, 1997, CATHETER CARDIO DIAG, V42, P113, DOI 10.1002/(SICI)1097-0304(199710)42:2<113::AID-CCD2>3.0.CO
[4]  
2-G
[5]   Clinical implications of intravascular ultrasound imaging for stenting procedures [J].
Bruining, N ;
Sabaté, M ;
Serruys, PW .
AMERICAN HEART JOURNAL, 1999, 137 (02) :207-210
[6]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[7]   Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography [J].
de Feyter, PJ ;
Kay, P ;
Disco, C ;
Serruys, PW .
CIRCULATION, 1999, 100 (17) :1777-1783
[8]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[9]  
Fitzgerald PJ, 2000, CIRCULATION, V102, P523
[10]   BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS [J].
GOLDBERG, SL ;
COLOMBO, A ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
TOBIS, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) :996-1003