Purpose The purpose of the current study was to determine whether there is any incremental benefit to routine intravascular ultrasound (IVUS) guidance of percutaneous coronary intervention. Methods and Results We compared the outcome of 796 patients who underwent an IVUS study (IVUS group) during the index stent procedure with 8274 patients who did not have an IVUS study (angiography group). The primary end point was the composite end point of death, myocardial infarction, or ischemia-driven target vessel revascularization within 9 months of the index stent procedure. There were statistically significant differences in multiple procedural characteristics. Most importantly, those patients who underwent an IVUS study had a larger postprocedural minimal lumen diameter and smaller postprocedural percent diameter stenosis. However, there was no significant difference between the IVUS group and the angiography group with respect to the primary end point (RR 1.10, 95% CI 0.91, 1.32) or any of the individual clinical end points. Adjustment for multiple clinical and procedural characteristics did not significantly alter these findings. Conclusions These data suggest that the routine performance of IVUS during stent placement influences the performance of the procedure, as judged by differences in procedural characteristics, but does not improve clinical outcome at 9 months.
引用
收藏
页码:501 / 506
页数:6
相关论文
共 27 条
[21]   Intravascular ultrasound - Novel pathophysiological insights and current clinical applications [J].
Nissen, SE ;
Yock, P .
CIRCULATION, 2001, 103 (04) :604-616
[22]   A CONSUMERS GUIDE TO SUBGROUP ANALYSES [J].
OXMAN, AD ;
GUYATT, GH .
ANNALS OF INTERNAL MEDICINE, 1992, 116 (01) :78-84
[23]  
RUSSO RJ, 1999, J AM COLL CARDIOL, V100, P1
[24]   Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: A multicenter, randomized study comparing two strategies - With and without intravascular ultrasound guidance [J].
Schiele, F ;
Meneveau, N ;
Vuillemenot, A ;
Zhang, DD ;
Gupta, S ;
Mercier, M ;
Danchin, N ;
Bertrand, B ;
Bassand, JP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (02) :320-328
[25]   Reduction of restenosis by vessel size adapted percutaneous transluminal coronary angioplasty using intravascular ultrasound [J].
Schroeder, S ;
Baumbach, A ;
Haase, KK ;
Oberhoff, M ;
Marholdt, H ;
Herdeg, C ;
Athanasiadis, A ;
Karsch, KR .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (06) :875-879
[26]  
Schwarzacher SP, 1997, CATHETER CARDIO DIAG, V40, P152
[27]   A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495