Migration and wear of hydroxyapatite-coated press-fit cups in revision hip arthroplasty -: A radiostereometric study

被引:29
作者
Nivbrant, B [1 ]
Kärrholm, J [1 ]
机构
[1] No Univ Hosp, Dept Orthoped, Umea, Sweden
关键词
hip; arthroplasty; uncemented; hydroxyapatite; micromotion;
D O I
10.1016/S0883-5403(97)90160-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Screw-fixated and hydroxyapatite-coated press-fit cups were studied using radiostereometry in 29 revision and 14 primary arthroplasties. The acetabular defects in the revision cases varied from none to type 3 (wall defects) according to Gustilo-Pasternak, Morsellized allograft was used in 25 revisions. Nine of these cups rested on less than 50% living bone. After 2 years, the mean migration in the revised group reached 0.36, 0.21, and 0.49 mm in the horizontal, longitudinal, and anteroposterior (AP) directions. The mean rotations varied between 0.5 degrees and 0.7 degrees depending on direction. The primary implants displayed smaller mediolateral migration and AP till. The mean proximal wear rate far the whole group was 0.11 mm/y. A central gap on the postoperative AP view implied less migration. The size of the preoperative bone defects or amount of bone-graft used had no influence on the migration. Despite extensive use of morsellized allograft, this implant displayed the smallest migration so far reported in revision hip arthroplasty.
引用
收藏
页码:904 / 912
页数:9
相关论文
共 27 条
[1]
BAUER TW, 1993, J ARTHROPLASTY, V8, P167, DOI 10.1016/S0883-5403(09)80010-7
[2]
BLOEBAUM RD, 1993, J ARTHROPLASTY, V8, P203, DOI 10.1016/S0883-5403(09)80014-4
[3]
FRANZEN H, 1993, CLIN ORTHOP RELAT R, P131
[4]
6-YEAR RESULTS OF HYDROXYAPATITE-COATED TOTAL HIP-REPLACEMENT [J].
GEESINK, RGT ;
HOEFNAGELS, NHM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (04) :534-547
[5]
HERNANDEZ JR, 1994, J BONE JOINT SURG BR, V76B, P263
[6]
SURFACE DAMAGE TO COBALT-CHROME FEMORAL-HEAD PROSTHESES [J].
JASTY, M ;
BRAGDON, CR ;
LEE, K ;
HANSON, A ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :73-77
[7]
DOES EARLY MICROMOTION OF FEMORAL STEM PROSTHESES MATTER - 4-7-YEAR STEREORADIOGRAPHIC FOLLOW-UP OF 84 CEMENTED PROSTHESES [J].
KARRHOLM, J ;
BORSSEN, B ;
LOWENHIELM, G ;
SNORRASON, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (06) :912-917
[8]
MIGRATION OF POROUS COATED ACETABULAR PROSTHESES FIXED WITH SCREWS - ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS [J].
KARRHOLM, J ;
SNORRASON, F .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (06) :826-835
[9]
KARRHOLM J, 1996, T ORTHOP RES SOC, V42, P239
[10]
Early migration predicts late aseptic failure of hip sockets [J].
Krismer, M ;
Stockl, B ;
Fischer, M ;
Bauer, R ;
Mayrhofer, P ;
Ogon, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03) :422-426