Feasibility and utility of respiratory-gated, gadolinium-enhanced T1-weighted magnetic resonance urography in children

被引:31
作者
Staatz, G
Nolte-Ernsting, CCA
Adam, GB
Hübner, D
Rohrmann, D
Stollbrink, C
Günther, RW
机构
[1] Rhein Westfal TH Aachen, Univ Hosp, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Rhein Westfal TH Aachen, Univ Hosp, Dept Urol, D-52057 Aachen, Germany
[3] Rhein Westfal TH Aachen, Univ Hosp, Dept Pediat, D-52057 Aachen, Germany
关键词
MR urography; genitourinary system; children;
D O I
10.1097/00004424-200008000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO evaluate the feasibility and utility of respiratory-gated, gadolinium-enhanced T1-weighted magnetic resonance (MR) urography in children. METHODS. In a prospective study, 30 consecutive children, aged 3 weeks to 13.8 years, underwent MR urography, After intravenous injection of low-dose furosemide and gadopentetate dimeglumine, respiratory-gated, coronal, T1-weighted 3D-gradient-echo sequences were obtained at 1.5 T 5 to 30 minutes after contrast administration. Postprocessing of the data was performed using a maximum-intensity projection algorithm, In addition, precontrast half-Fourier rapid acquisition with relaxation enhancement MR urograms were obtained in 29 children. RESULTS. Respiratory-gated, T1-weighted MR urography was successfully performed in all children without the need for sedation. Compared with the final diagnosis, prospective analysis of MR urography images revealed the correct diagnosis in 56 of 58 pelvicaliceal systems (96%). The ureteral morphology was correctly evaluated in 59 of 64 ureters (92%), The method showed limited efficiency for evaluating nonfunctioning renal units. CONCLUSIONS. Respiratory-gated, gadolinium-enhanced T1-weighted MR urography is a feasible and effective diagnostic tool in the assessment of upper urinary tract morphology in children. It is especially useful in depicting nondilated collecting systems and ureters.
引用
收藏
页码:504 / 512
页数:9
相关论文
共 22 条
[11]   Gadolinium-enhanced excretory MR urography after low-dose diuretic injection:: Comparison with conventional excretory urography [J].
Nolte-Ernsting, CCA ;
Bücker, A ;
Adam, GB ;
Neuerburg, JM ;
Jung, P ;
Hunter, DW ;
Jakse, G ;
Günther, RW .
RADIOLOGY, 1998, 209 (01) :147-157
[12]   Contrast-enhanced magnetic resonance urography - First experimental results with a polymeric gadolinium bloodpool agent [J].
NolteErnsting, C ;
Adam, G ;
Bucker, A ;
Berges, S ;
Bjornerud, A ;
Gunther, RW .
INVESTIGATIVE RADIOLOGY, 1997, 32 (07) :418-423
[13]   MR urography: Evaluation of a three-dimensional fast spin-echo technique in patients with hydronephrosis [J].
OMalley, ME ;
Soto, JA ;
Yucel, EK ;
Hussain, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (02) :387-392
[14]   MR urography using HASTE imaging in the assessment of ureteric obstruction [J].
Regan, F ;
Bohlman, ME ;
Khazan, R ;
Rodriguez, R ;
SchultzeHaakh, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (05) :1115-1120
[15]   MR UROGRAPHY - TECHNIQUE AND APPLICATION [J].
ROTHPEARL, A ;
FRAGER, D ;
SUBRAMANIAN, A ;
BASHIST, B ;
BAER, J ;
KAY, C ;
COOKE, K ;
RAIA, C .
RADIOLOGY, 1995, 194 (01) :125-130
[16]   MR urography in the evaluation of urinary tract obstruction [J].
Roy, C ;
Saussine, C ;
Guth, S ;
Horviller, S ;
Tuchmann, C ;
Vasilescu, C ;
Le Bras, Y ;
Jacqmin, D .
ABDOMINAL IMAGING, 1998, 23 (01) :27-34
[17]   EVALUATION OF RARE-MR UROGRAPHY IN THE ASSESSMENT OF URETEROHYDRONEPHROSIS [J].
ROY, C ;
SAUSSINE, C ;
JAHN, C ;
VINEE, P ;
BEAUJEUX, R ;
CAMPOS, M ;
GOUNOT, D ;
CHAMBRON, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (04) :601-608
[18]   Contrast media research [J].
Runge, VM .
INVESTIGATIVE RADIOLOGY, 1999, 34 (12) :785-790
[19]   PRELIMINARY EVALUATION - MAGNETIC-RESONANCE OF UROGRAPHY USING A SATURATION INVERSION PROJECTION SPIN-ECHO SEQUENCE [J].
SCHAD, LR ;
SEMMLER, W ;
KNOPP, MV ;
DEIMLING, M ;
WEINMANN, HJ ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :319-327
[20]   OBSTRUCTIVE NEPHROPATHY - EVALUATION WITH DYNAMIC GD-DTPA ENHANCED MR IMAGING [J].
SEMELKA, RC ;
HRICAK, H ;
TOMEI, E ;
FLOTH, A ;
STOLLER, M .
RADIOLOGY, 1990, 175 (03) :797-803