Intravascular ultrasound comparison of Sirolimus-eluting stent versus bare metal stent implantation in diseased saphenous vein grafts (from the RRISC [Reduction of restenosis in saphenous vein grafts with cypher sirolimus-eluting stent] trial)

被引:15
作者
Agostoni, Pierfrancesco [1 ]
Vermeersch, Paul
Semeraro, Oscar
Verheye, Stefan
Van Langenhove, Glenn
Van den Heuvel, Paul
Convens, Carl
Van den Branden, Frank
Bruining, Nico
机构
[1] Antwerp Cardiovasc Inst Middleheim, AZ Middleheim, Antwerp, Belgium
[2] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
关键词
D O I
10.1016/j.amjcard.2007.02.052
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The randomized Reduction of Restenosis In Saphenous Vein Grafts with Cypher Sirolimus-Eluting Stent trial compared angiographic outcomes of sirolimus-eluting stents (SESs) versus bare metal stents (BMSs) in saphenous vein grafts (SVG). Using intravascular ultrasound (IVUS) performed during 6-month follow-up angiography, we compared the vascular effects of the 2 types of stent on SVGs. of 75 patients (96 lesions) included, 59 patients underwent IVUS in 61 SVGs; 29 patients received 40 SESs for 34 lesions, and 30 patients received 42 BMSs for 39 lesions. IVUS parameters (diameters, areas, and volumes) were compared in the 2 groups. A specific analysis was performed for overlapping SESs. Median neointimal volume was 1.3 mm(3) (interquartile range 0 to 13.1) in SESs versus 24.5 (7.8 to 39.5) in BMSs (p <0.001). Minimal incomplete stent apposition was detected at only 3 stent edges (2 BMSs, 1 SES) next to ectatic regions of the SVG. Compared with single SESs, overlapping SESs showed significant increases in neointimal reaction, with a neointimal volume of 0.6 mm(3)/mm of stent (0.1 to 1.8) versus 0 (0 to 0.4) in single SESs (p = 0.03), and this phenomenon was mainly localized in overlapping SES segments, where neointimal volume per millimeter of stent was 1.1 mm(3)/mm (0.6 to 4.4) versus 0 (0 to 1.3) in nonoverlapping segments (p = 0.05). In conclusion, SESs effectively inhibit neointimal hyperplasia volume compared with BMSs in diseased vein grafts, without evidence of increased incomplete apposition risk. The neointimal response to overlapping SES layers seems higher than to a single SES layer. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:52 / 58
页数:7
相关论文
共 20 条
[1]  
Bruining N, 1998, CATHETER CARDIO DIAG, V43, P254, DOI 10.1002/(SICI)1097-0304(199803)43:3<254::AID-CCD3>3.0.CO
[2]  
2-8
[3]   THE BIOLOGY OF SAPHENOUS-VEIN GRAFT OCCLUSION - ETIOLOGY AND STRATEGIES FOR PREVENTION [J].
BRYAN, AJ ;
ANGELINI, GD .
CURRENT OPINION IN CARDIOLOGY, 1994, 9 (06) :641-649
[4]  
Costa Marco, 2005, J Invasive Cardiol, V17, P396
[5]   Retrospective image-based gating of intracoronary ultrasound images for improved quantitative analysis: The intelligate method [J].
de Winter, SA ;
Hamers, R ;
Degertekin, M ;
Tanabe, K ;
Lemos, PA ;
Serruys, PW ;
Roelandt, JRTC ;
Bruining, N .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (01) :84-94
[6]   Intravascular ultrasound evaluation after sirolimus eluting stent implantation for de novo and in-stent restenosis lesions [J].
Degertekin, M ;
Lemos, PA ;
Lee, CH ;
Tanabe, K ;
Sousa, JE ;
Abizaid, A ;
Regar, E ;
Sianos, G ;
van der Giessen, WJ ;
de Feyter, PJ ;
Wuelfert, E ;
Popma, JJ ;
Serruys, PW .
EUROPEAN HEART JOURNAL, 2004, 25 (01) :32-38
[7]   Pathology of restenosis in saphenous bypass grafts after long-term stent implantation [J].
Depre, C ;
Havaux, X ;
Wijns, W .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 110 (03) :378-384
[8]   A novel approach to quantitative analysis of intra vascular ultrasound images [J].
Hamers, R ;
Bruining, N ;
Knook, M ;
Sabate, M ;
Roelandt, JRTC .
COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 :589-592
[9]   Relation of final lumen dimensions in saphenous vein grafts after stent implantation to outcome [J].
Iakovou, I ;
Dangas, G ;
Mintz, GS ;
Mehran, R ;
Kobayashi, Y ;
Aymong, ED ;
Hirose, M ;
Ashby, DT ;
Lansky, AJ ;
Stone, GW ;
Leon, MB ;
Moses, JW .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (08) :963-968
[10]   Vascular effects of sirolimus-eluting versus bare-metal stents in diabetic patients -: Three-dimensional ultrasound results of the diabetes and sirolimus-eluting stent (DIABETES) trial [J].
Jimenez-Quevedo, Pilar ;
Sabate, Manel ;
Angiolillo, Dominick J. ;
Costa, Marco A. ;
Alfonso, Fernando ;
Gomez-Hospital, Joan Antoni ;
Hernandez-Antolin, Rosana ;
Banuelos, Camino ;
Goicolea, Javier ;
Fernandez-Aviles, Francisco ;
Bass, Theodore ;
Escaned, Javier ;
Moreno, Raul ;
Fernandez, Cristina ;
Macaya, Carlos .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (11) :2172-2179