Development and validation of analytical methodology using capillary electrophoresis for separation and determination of anions in rainwater

被引:34
作者
Fung, YS [1 ]
Lau, KM [1 ]
机构
[1] Univ Hong Kong, Dept Chem, Hong Kong, Hong Kong
关键词
acid rain; anion analysis; capillary electrophoresis; organic anion analysis; trace analysis;
D O I
10.1016/S0039-9140(97)00284-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new capillary electrophoresis (CE) procedure was developed for simultaneous determination of both organic and inorganic anions in rain water using a background electrolyte (BGE) containing 5 mM molybdate, 0.15 mM CTAH, 0.01% PVA and 5 mM Tris buffer to adjust pH at 7.9. Under optimised conditions, good repeatability (RSD for sulphate in migration time = 0.36% and peak area = 4.2%), low detection limit (2 ppb for chloride) and satisfactory working range (50 ppb-20 ppm for hydrodynamic injection, 10 ppb-3 ppm for electrokinetic injection for chloride) were obtained. The reliability of the CE procedure developed was established by satisfactory recovery tests and good agreement of results obtained by both the CE and ion chromatography (IC) methods. The procedure developed had been successfully applied for field monitoring of rainwater showing good repeatability and capability of detecting trace anions at ppb levels beyond the IC working range. Thus, the new CE procedure developed provides a quick, sensitive, economic and reliable method to meet the need for the simultaneous determination of both organic and inorganic anions in the acid rain monitoring programme. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:641 / 656
页数:16
相关论文
共 41 条
[1]  
BAUER EL, 1971, STAT MAN CHEM
[2]   NEW APPROACH TO THE ANALYSIS OF LOW-LEVELS OF ANIONS IN WATER [J].
BONDOUX, G ;
JANDIK, P ;
JONES, WR .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :79-88
[3]   OPTIMIZATION OF INDIRECT UV DETECTION IN CAPILLARY ZONE ELECTROPHORESIS OF LOW-MOLECULAR-MASS ANIONS [J].
BUCHBERGER, W ;
COUSINS, SM ;
HADDAD, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (08) :313-319
[4]   LARGE-VOLUME STACKING OF ANIONS IN CAPILLARY ELECTROPHORESIS USING AN ELECTROOSMOTIC FLOW MODIFIER AS A PUMP [J].
BURGI, DS .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3726-3729
[5]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[6]  
CONSINS SM, 1994, J CHROMATOGR A, V671, P397
[7]   APPLICATION OF CAPILLARY ELECTROPHORESIS IN ATMOSPHERIC AEROSOLS ANALYSIS - DETERMINATION OF INORGANIC AND ORGANIC-ANIONS [J].
DABEKZLOTORZYNSKA, E ;
DLOUHY, JF .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :389-395
[8]   SUPPRESSED CONDUCTOMETRIC CAPILLARY ELECTROPHORESIS SEPARATION SYSTEMS [J].
DASGUPTA, PK ;
BAO, LY .
ANALYTICAL CHEMISTRY, 1993, 65 (08) :1003-1011
[9]   ONLINE FIBER OPTIC UV DETECTION CELL AND CONDUCTIVITY CELL FOR CAPILLARY ZONE ELECTROPHORESIS [J].
FORET, F ;
DEML, M ;
KAHLE, V ;
BOCEK, P .
ELECTROPHORESIS, 1986, 7 (09) :430-432
[10]   Determination of total organic carbon in water by thermal combustion-ion chromatography [J].
Fung, YS ;
Wu, ZC ;
Dao, KL .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2186-2190