Use of two real-time polymerase chain reactions (PCRs) to detect herpes simplex type 1 and 2-DNA after automated extraction of nucleic acid

被引:14
作者
Mengelle, C [1 ]
Sandres-Sauné, K [1 ]
Miédougé, M [1 ]
Mansuy, JM [1 ]
Bouquies, C [1 ]
Izopet, J [1 ]
机构
[1] CHU Toulouse, Hop Purpan, Virol Lab, F-31059 Toulouse 9, France
关键词
HSV infection; Light Cycler; laboratory diagnosis;
D O I
10.1002/jmv.20198
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Herpes simplex virus infections may be diagnosed by several techniques, including conventional cell culture and the polymerase chain reaction (PCR). This prospective study compares the analytical performances and usefulness of an in-house real-time PCR method and the Light Cycler HSV1/(2) detection kit(TM) (Roche Diagnostics, Mannheim, Germany). The results of both PCRs were then compared to those obtained by conventional cell culture. A total of 313 samples were tested (70 dermal samples, 81 cerebrospinal fluids (CSF), 47 ocular, 42 anogenital, 34 throat swabs, and 33 oral samples, 3 whole blood, 2 biopsies, and 1 bronchoalveolar lavage). Samples for molecular assays were extracted twice with the MagNa Pure instrument(TM) (Roche Molecular Biochemicals, Mannheim, Germany) and tested blind in parallel by the two PCR methods. Most (226) samples were also examined by cell culture. Forty three samples were found positive by both PCRs, whereas 267 were negative. The HSV-1 and -2 typing of positive samples was identical. Three of the samples were positive in the in-house PCR and negative in the Light Cycler HSV1/(2) detection kit. There was no statistically significant difference between the two tests. Only one sample gave an invalid result due to negative PCR and negative internal control result. Seven samples were positive by both real-time PCRs and negative in conventional culture. The PCRs were significantly (P<0.05) more sensitive. The results show good agreement between the two real-time PCR methods, with the molecular tests being more sensitive than cell culture. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:459 / 462
页数:4
相关论文
共 12 条
[11]   Diagnosing herpesvirus infections by real-time amplification and rapid culture [J].
van Doornum, GJJ ;
Guldemeester, J ;
Osterhaus, ADME ;
Niesters, HGM .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (02) :576-580
[12]   Rapid detection of herpes simplex virus and varicella-zoster virus infections by real-time PCR [J].
Weidmann, M ;
Meyer-König, U ;
Hufert, FT .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (04) :1565-1568