Fast and simultaneous determination of darunavir and eleven other antiretroviral drugs for therapeutic drug monitoring: method development and validation for the determination of all currently approved HIV protease inhibitors and non-nucleoside reverse transcriptase inhibitors in human plasma by liquid chromatography coupled with electrospray ionization tandem mass spectrometry

被引:76
作者
ter Heine, Rob
Aiderden-Los, Carolien G.
Rosing, Hilde
Hillebrand, Michel J. X.
van Gorp, Eric C. M.
Huitema, Alwin D. R.
Beijnen, Jos H.
机构
[1] Slotervaart Hosp, Dept Pharm & Pharmacol, NL-1066 EC Amsterdam, Netherlands
[2] Slotervaart Hosp, Dept Internal Med, NL-1066 EC Amsterdam, Netherlands
关键词
D O I
10.1002/rcm.3119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For the quantification of all currently approved non-nucleoside reverse transcriptase inhibitors and protease inhibitors, including the new protease inhibitor darunavir and the active nelfinavir metabolite M8, an assay was developed, using liquid chromatography coupled with tandem mass spectrometry. The sample pretreatment consisted of a protein precipitation with a mixture of methanol and acetonitrile using only 100 mu L plasma. Chromatographic separation was performed on a reversed-phase C18 column (130 x 2.0 mm, particle size 5 mu m) with a quick stepwise gradient using an acetate buffer (pH 5) and methanol, at a flow rate of 0.23 mL/min. The analytical run time was only 10 min. The triple quadrupole mass spectrometer was operated in the positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over a range of 0.1 to 20 mu g/mL for amprenavir, atazanavir, efavirenz, indinavir, lopinavir, nelfinavir, the active nelfinavir metabolite M8, nevirapine and ritonavir, a range of 0.03 to 10 mu g/mL for saquinavir and darunavir and a range of 0.3 to 100 mu g/mL for tipranavir, based on observed concentration ranges in patients treated with these drugs. D5-squinavir, D6-indinavir, 13C6-efavirenz and dibenzepine were used as internal standards. The method was proven to be specific, accurate, precise and robust. Accuracies ranged from 88.3% to 102.2% and all precisions were less than 9.3%. Furthermore, the assay demonstrates a high sensitivity for all analytes and the stepwise gradient allows addition of new analytes into the same method. The method is now successfully applied for routine therapeutic drug monitoring and pharmacokinetic studies in HIV-infected patients. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:2505 / 2514
页数:10
相关论文
共 17 条
[1]   Therapeutic drug monitoring - An aid to optimising response to antiretroviral drugs? [J].
Aarnoutse, RE ;
Schapiro, JM ;
Boucher, CAB ;
Hekster, YA ;
Burger, DM .
DRUGS, 2003, 63 (08) :741-753
[2]  
[Anonymous], GUID IND BIOAN METH
[3]   An update on therapeutic drug monitoring for antiretroviral drugs [J].
Back, David ;
Gibbons, Sara ;
Khoo, Saye .
THERAPEUTIC DRUG MONITORING, 2006, 28 (03) :468-473
[4]  
Bartlett JG, 2006, GUIDELINES USE ANTIR
[5]   Simultaneous quantification of the new HIV protease inhibitors atazanavir and tipranavir in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry [J].
Crommentuyn, KML ;
Rosing, H ;
Hillebrand, MJX ;
Huitema, ADR ;
Beijnen, JH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (02) :359-367
[6]   Rapid quantification of HIV protease inhibitors in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry [J].
Crommentuyn, KML ;
Rosing, H ;
Nan-Offeringa, LGAH ;
Hillebrand, MJX ;
Huitema, ADR ;
Beijnen, JH .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (02) :157-166
[7]   Simultaneous determination of HIV protease inhibitors amprenavir, atazanavir, indinavir, lopinavir, nelfinavir, ritonavir and saquinavir in human plasma by high-performance liquid chromatography-tandem mass spectrometry [J].
Dickinson, L ;
Robinson, L ;
Tjia, J ;
Khoo, S ;
Back, D .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2) :82-90
[8]   Simultaneous determination of the HIV drugs indinavir, amprenavir, saquinavir, ritonavir, lopinavir, nelfinavir, the nelfinavir hydroxymetabolite M8, and nevirapine in human plasma by reversed-phase high-performance liquid chromatography [J].
Droste, JAH ;
Verweij-van Wissen, CPWGM ;
Burger, DM .
THERAPEUTIC DRUG MONITORING, 2003, 25 (03) :393-399
[9]   Automated, fast, and sensitive quantification of drugs human plasma by LC/LC-MS - Quantification of 6 protease inhibitors and 3 nonnucleoside transcriptase inhibitors [J].
Egge-Jacobsen, W ;
Unger, M ;
Niemann, CU ;
Baluom, M ;
Hirai, S ;
Benet, LZ ;
Christians, U .
THERAPEUTIC DRUG MONITORING, 2004, 26 (05) :546-562
[10]   Simple and rapid method for the simultaneous determination of the non-nucleoside reverse transcriptase inhibitors efavirenz and nevirapine in human plasma using liquid chromatography [J].
Kappelhoff, BS ;
Rosing, H ;
Huitema, ADR ;
Beijnen, JH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02) :353-362