Simple and rapid method for the simultaneous determination of the non-nucleoside reverse transcriptase inhibitors efavirenz and nevirapine in human plasma using liquid chromatography

被引:46
作者
Kappelhoff, BS
Rosing, H
Huitema, ADR
Beijnen, JH
机构
[1] Slotervaart Hosp, Dept Pharm & Pharmacol, NL-1066 EC Amsterdam, Netherlands
[2] Fac Pharmaceut Sci, Div Drug Toxicol, Dept Biomed Anal, NL-3508 TB Utrecht, Netherlands
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 792卷 / 02期
关键词
efavirenz; nevirapine;
D O I
10.1016/S1570-0232(03)00325-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Efavirenz and nevirapine are non-nucleoside reverse transcriptase inhibitors for the treatment of HIV-1-infected individuals. A simple and rapid high-performance liquid chromatographic method for the simultaneous quantification of efavirenz and nevirapine in human plasma suitable for therapeutic drug monitoring is described. Sample pre-treatment consisted of protein precipitation with acetonitrile and subsequently dilution with distilled water. The drugs were separated from endogenous compounds by isocratic reversed-phase high-performance liquid chromatography with ultraviolet detection at 275 nm. The method was validated over the therapeutically relevant concentration range of 0.05-15.0 mg l(-1) and 0.25-15.0 mg l(-1) for efavirenz and nevirapine, respectively, using a volume of 100 mul of plasma. The calibration curves were linear over this concentration range. Carbamazepine was used as internal standard. The assay proved to be accurate (accuracies varied between -12.7 and 8.5%) and precise (intra- and inter-assay precisions were less then 5.9%). The tested batches of control human plasma and frequently co-administered drugs did not interfere with the described methodology. Efavirenz and nevirapine were stable under various relevant storage conditions. This validated assay is suited for use in pharmacokinetic studies with efavirenz and nevirapine and can readily be implemented in the setting of a hospital laboratory for the monitoring of efavirenz and nevirapine concentrations. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:353 / 362
页数:10
相关论文
共 11 条
[1]   Efavirenz [J].
Adkins, JC ;
Noble, S .
DRUGS, 1998, 56 (06) :1055-1064
[2]   Determination of twelve antiretroviral agents in human plasma sample using reversed-phase high-performance liquid chromatography [J].
Aymard, G ;
Legrand, M ;
Trichereau, N ;
Diquet, B .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 744 (02) :227-240
[3]   Efavirenz plasma levels can predict treatment failure and central nervous system side effects in HIV-1-infected patients [J].
Marzolini, C ;
Telenti, A ;
Decosterd, LA ;
Greub, G ;
Biollaz, J ;
Buclin, T .
AIDS, 2001, 15 (01) :71-75
[4]   Simple and rapid quantification of the non-nucleoside reverse transcriptase inhibitors nevirapine, delavirdine, and efavirenz in human blood plasma using high-performance liquid chromatography with ultraviolet absorbance detection [J].
Rezk, NL ;
Tidwell, RR ;
Kashuba, ADM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (01) :79-88
[5]   Bioanalytical liquid chromatographic method validation. A review of current practices and procedures [J].
Rosing, H ;
Man, WY ;
Doyle, E ;
Bult, A ;
Beijnen, JH .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (03) :329-354
[6]   Determination of serum levels of thirteen human immunodeficiency virus-suppressing drugs by high-performance liquid chromatography [J].
Simon, VA ;
Thiam, MD ;
Lipford, LC .
JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) :447-453
[7]   High-performance liquid chromatographic method for the simultaneous determination of the six HIV-protease inhibitors and two non-nucleoside reverse transcriptase inhibitors in human plasma [J].
Titier, K ;
Lagrange, F ;
Péhourcq, F ;
Edno-Mcheik, L ;
Moore, N ;
Molimard, M .
THERAPEUTIC DRUG MONITORING, 2002, 24 (03) :417-424
[8]   Simultaneous quantitative assay of six HIV protease inhibitors, one metabolite, and two non-nucleoside reverse transcriptase inhibitors in human plasma by isocratic reversed-phase liquid chromatography [J].
Tribut, O ;
Arvieux, C ;
Michelet, C ;
Chapplain, JM ;
Allain, H ;
Bentué-Ferrer, D .
THERAPEUTIC DRUG MONITORING, 2002, 24 (04) :554-562
[9]   High exposure to nevirapine in plasma is associated with an improved virological response in HIV-1-infected individuals [J].
Veldkamp, AI ;
Weverling, GJ ;
Lange, JMA ;
Montaner, JSG ;
Reiss, P ;
Cooper, DA ;
Vella, S ;
Hall, D ;
Beijnen, JH ;
Hoetelmans, RMW .
AIDS, 2001, 15 (09) :1089-1095
[10]   Quantitative determination of efavirenz (DMP 266), a novel non-nucleoside reverse transcriptase inhibitor, in human plasma using isocratic reversed-phase high-performance liquid chromatography with ultraviolet detection [J].
Veldkamp, AI ;
van Heeswijk, RPG ;
Meenhorst, PL ;
Mulder, JW ;
Lange, JMA ;
Beijnen, JH ;
Hoetelmans, RMW .
JOURNAL OF CHROMATOGRAPHY B, 1999, 734 (01) :55-61