Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty

被引:37
作者
Huang, Tsan-Wen [1 ,2 ]
Peng, Kuo-Ti [1 ,2 ]
Huang, Kuo-Chin [2 ,3 ]
Lee, Mel S. [1 ,2 ]
Hsu, Robert Wen-Wei [1 ,2 ]
机构
[1] Chang Gung Mem Hosp, Div Joint Reconstruct, Dept Orthopaed Surg, Chiayi, Taiwan
[2] Chang Gung Univ, Tao Yuan, Taiwan
[3] Chang Gung Mem Hosp, Div Orthopaed Traumatol, Dept Orthopaed Surg, Chiayi, Taiwan
关键词
Total knee arthroplasty; Extra-articular deformity of the femur; Coronal femoral bowing deformity; Computer-assisted surgery; Computed tomography; EXTRAARTICULAR DEFORMITY; POSTOPERATIVE ALIGNMENT; NAVIGATION SUPPORT; AXIAL ALIGNMENT; ASIAN PATIENTS; CORONAL PLANE; REPLACEMENT; SYSTEM; INSTRUMENTATION; TRIAL;
D O I
10.1007/s00167-014-3331-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Marked coronal femoral bowing may bear a risk for mal-alignment of femoral component and reconstructed mechanical axis (MA) by using conventional instrumentations. The aim of this study was to investigate the usefulness of computer-assisted surgery-total knee arthroplasty (CAS-TKA) under this circumstance. We retrospectively analyzed patients with osteoarthritic knee and marked coronal femoral bowing who underwent TKA at our institution. The CAS-TKA and the conventional techniques were compared by radiographic parameters in coronal and sagittal planes, and rotational alignment of femoral component was assessed by computed tomography (CT) scans. The Hospital for Special Surgery (HSS) and International Knee Society (IKS) scores were obtained for all patients preoperatively and at the last follow-up. A total of 65 knees were enrolled in this study. Twenty-eight TKAs implanted using a CT-free navigation system, and the remaining 37 TKAs implanted using the conventional technique. CAS-TKAs were more consistent than conventional TKAs in aiding proper postoperative MA and ideal alignments of femoral component in the coronal and sagittal planes. However, CAS-TKA group was not obtained at significantly higher rates of femoral component in axial plane. At a mean follow-up of 43 months, there was no significant difference in HSS and IKS scores between the groups. Although CAS-TKA did not have superior functional outcomes in the short-term follow-up, proper coronal and sagittal alignment of femoral component and postoperative MA were obtained in patients with marked coronal femoral bowing. The long-term follow-up will be needed to clarify the eventual benefits. Retrospective comparative study, Level III.
引用
收藏
页码:2954 / 2961
页数:8
相关论文
共 46 条
[1]
Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial [J].
Boonen, B. ;
Schotanus, M. G. M. ;
Kerens, B. ;
van der Weegen, W. ;
van Drumpt, R. A. M. ;
Kort, N. P. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) :2206-2212
[2]
Imageless Navigation System Does Not Improve Component Rotational Alignment in Total Knee Arthroplasty [J].
Cheng, Tao ;
Zhang, Guoyou ;
Zhang, Xianlong .
JOURNAL OF SURGICAL RESEARCH, 2011, 171 (02) :590-600
[3]
Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation [J].
Decking, R ;
Markmann, Y ;
Fuchs, J ;
Puhl, W ;
Scharf, HP .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :282-288
[4]
Patient-Specific Versus Conventional Instrumentation for Total Knee Arthroplasty: Peri-Operative and Cost Differences [J].
DeHaan, Alexander M. ;
Adams, Jacob R. ;
DeHart, Matthew L. ;
Huff, Thomas W. .
JOURNAL OF ARTHROPLASTY, 2014, 29 (11) :2065-2069
[5]
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[6]
Coronal Alignment in Total Knee Arthroplasty Just How Important is it? [J].
Fang, David M. ;
Ritter, Merrill A. ;
Davis, Kenneth E. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (06) :39-43
[7]
When computer-assisted knee replacement is the best alternative [J].
Fehring, Thomas K. ;
Mason, J. Bohannon ;
Moskal, Joseph ;
Pollock, David C. ;
Mann, John ;
Williams, Vincent J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) :132-136
[8]
No difference in mechanical alignment and femoral component placement between patient-specific instrumentation and conventional instrumentation in TKA [J].
Fu, Huichao ;
Wang, Jiaxing ;
Zhou, Shenyuan ;
Cheng, Tao ;
Zhang, Wen ;
Wang, Qi ;
Zhang, Xianlong .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (11) :3288-3295
[9]
HSU RWW, 1990, CLIN ORTHOP RELAT R, P215
[10]
Effect of preoperative deformity on postoperative leg axis in total knee arthroplasty: a prospective randomized study [J].
Hsu, Wei-Hsiu ;
Hsu, Robert Wen Wei ;
Weng, Yi-Jan .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (10) :1323-1327