Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery

被引:87
作者
Bin, Seong Il [1 ]
Nam, Tae Seok [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Orthoped Surg, Seoul 138736, South Korea
关键词
total knee arthroplasty; high-flex implants; maximal flexion; range of motion;
D O I
10.1007/s00167-006-0202-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared clinical [ including maximal flexion and range of motion ( ROM)] and radiographical outcomes of high-flex versus conventional implants for total knee arthroplasty (TKA) after 1 year. We also analyzed the factors affecting postoperative ROM in high-flex implants. The high-flex group (n = 90) had an average maximal flexion of 129.8 degrees ( standard deviation (SD), 5.2 degrees) significantly higher than the 124.3 degrees ( SD, 9.2 degrees) of the conventional group ( n = 90), especially for patients with less than 90 degrees of knee flexion ( P < 0.05). There was no significant difference in hospital for special surgery (HSS) score between the two groups. No knee developed osteolysis, aseptic loosening, or other complications. We found that, for high-flex implants, preoperative ROM had a significant effect on postoperative ROM.
引用
收藏
页码:350 / 355
页数:6
相关论文
共 26 条
[1]  
ALEJANDRO L, 1997, J BONE JOINT SURG, V79, P626
[2]  
Anouchi YS, 1996, CLIN ORTHOP RELAT R, P87
[3]   In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty [J].
Argenson, JNA ;
Scuderi, GR ;
Komistek, RD ;
Scott, WN ;
Kelly, MA ;
Aubaniac, JM .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :277-284
[4]   Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset [J].
Bellemans, J ;
Banks, S ;
Victor, J ;
Vandenneucker, H ;
Moemans, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :50-53
[5]  
Chew JTH, 1997, CLIN ORTHOP RELAT R, P87
[6]   TRADEOFFS BETWEEN MOTION AND STABILITY IN POSTERIOR SUBSTITUTING KNEE ARTHROPLASTY DESIGN [J].
DELP, SL ;
KOCMOND, JH ;
STERN, SH .
JOURNAL OF BIOMECHANICS, 1995, 28 (10) :1155-&
[7]  
Dennis DA, 1998, CLIN ORTHOP RELAT R, P47
[8]   Range of motion after total knee arthroplasty - The effect of implant design and weight-bearing conditions [J].
Dennis, DA ;
Komistek, RD ;
Stiehl, JB ;
Walker, SA ;
Dennis, KN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :748-752
[9]  
GUOAN L, 2004, J BONE JOINT SURG AM, V86, P1721
[10]   The early results of high-flex total knee arthroplasty - A minimum of 2 years of follow-up [J].
Huang, HT ;
Su, AY ;
Wang, GJ .
JOURNAL OF ARTHROPLASTY, 2005, 20 (05) :674-679