A new molecularly imprinted polymer (MIP)-based electrochemical sensor for monitoring 2,4,6-trinitrotoluene (TNT) in natural waters and soil samples

被引:212
作者
Alizadeh, Taher [1 ]
Zare, Mashaalah [2 ]
Ganjali, Mohamad Reza [2 ,3 ]
Norouzi, Parviz [2 ,3 ]
Tavana, Babak [2 ]
机构
[1] Univ Mohaghegh Ardabili, Fac Sci, Dept Appl Chem, Ardebil, Iran
[2] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[3] Univ Tehran Med Sci, Med Nanotechnol Res Ctr, Tehran, Iran
关键词
2,4,6-Trinitrotoluene; Molecularly imprinted polymer; Voltammetric sensor; Carbon paste; RECOGNITION; EXPLOSIVES; ACID;
D O I
10.1016/j.bios.2009.10.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A high selective voltammetric sensor for 2,4,6-trinitrotoluene (TNT) was introduced. TNT selective MIP and non-imprinted polymer(NIP) were synthesized and then used for carbon paste (CP) electrode preparation. The MIP, incorporated in the carbon paste electrode, functioned as selectively recognition element and pre-concentrator agent for TNT determination. The prepared electrode was used for TNT measurement by the three steps procedure, including analyte extraction in the electrode, electrode washing and electrochemical measurement of TNT. The MIP-CP electrode showed very high recognition ability in comparison to NIP-CP. It was shown that electrode washing after TNT extraction led to enhanced selectivity. The response of square wave voltammetry for TNT determination by proposed electrode was higher than that of differential pulse voltammetry. Some parameters affecting sensor response were optimized and then a calibration curve plotted. A dynamic linear range of 5 x 10(-9) to 1 x 10(-6) Mol l(-1) was obtained. The detection limit of the sensor was calculated equal to 1.5 x 10(-9) mol l(-1). This sensor was used successfully for TNT determination in different water and soil samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1166 / 1172
页数:7
相关论文
共 36 条
[1]   Rapid voltammetric determination of nitroaromatic explosives at electrochemically activated carbon-fibre electrodes [J].
Agüí, L ;
Vega-Montenegro, D ;
Yáñez-Sedeño, P ;
Pingarrón, JM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (02) :381-387
[2]   ENANTIOMERIC RESOLUTION OF AMINO-ACID DERIVATIVES ON MOLECULARLY IMPRINTED POLYMERS AS MONITORED BY POTENTIOMETRIC MEASUREMENTS [J].
ANDERSSON, LI ;
MIYABAYASHI, A ;
OSHANNESSY, DJ ;
MOSBACH, K .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (02) :323-331
[3]   Gas phase detection of explosives such as 2,4,6-trinitrotoluene by molecularly imprinted polymers [J].
Bunte, Gudrun ;
Huerttlen, Juergen ;
Pontius, Heike ;
Hartlieb, Kerstin ;
Krause, Horst .
ANALYTICA CHIMICA ACTA, 2007, 591 (01) :49-56
[4]   Non-covalent and semi-covalent molecularly imprinted polymers for selective on-line solid-phase extraction of 4-nitrophenol from water samples [J].
Caro, E ;
Masqué, M ;
Marcé, RM ;
Borrull, F ;
Cormack, PAG ;
Sherrington, DC .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :169-178
[5]   Polymeric receptors for the recognition of folic acid and related compounds via substructure imprinting [J].
Hall, Andrew J. ;
Quaglia, Milena ;
Manesiotis, Panagiotis ;
De Lorenzi, Ersilia ;
Sellergren, Boerje .
ANALYTICAL CHEMISTRY, 2006, 78 (24) :8362-8367
[6]   Molecularly imprinted polymers and their use in biomimetic sensors [J].
Haupt, K ;
Mosbach, K .
CHEMICAL REVIEWS, 2000, 100 (07) :2495-2504
[7]   Determination of explosives in soil and ground water by liquid chromatography-amperometric detection [J].
Hilmi, A ;
Luong, JHT ;
Nguyen, AL .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :97-110
[8]   Molecularly imprinted xerogels as platforms for sensing [J].
Holthoff, Ellen L. ;
Bright, Frank V. .
ACCOUNTS OF CHEMICAL RESEARCH, 2007, 40 (09) :756-767
[9]   Molecularly templated materials in chemical sensing [J].
Holthoff, Ellen L. ;
Bright, Frank V. .
ANALYTICA CHIMICA ACTA, 2007, 594 (02) :147-161
[10]   Metallic nanoparticle-carbon nanotube composites for electrochemical determination of explosive nitroaromatic compounds [J].
Hrapovic, Sabahudin ;
Majid, Ehsan ;
Liu, Yali ;
Male, Keith ;
Luong, John H. T. .
ANALYTICAL CHEMISTRY, 2006, 78 (15) :5504-5512