A protocol for high-frequency oscillatory ventilation in adults: Results from a roundtable discussion

被引:87
作者
Fessler, Henry E. [1 ]
Derdak, Stephen
Ferguson, Niall D.
Hager, David N.
Kacmarek, Robert M.
Thompson, Taylor
Brower, Roy G.
机构
[1] Johns Hopkins Med Inst, Div Pulm & Crit Care Med, Baltimore, MD 21205 USA
[2] Wilford Hall USAF Med Ctr, San Antonio, TX USA
[3] Univ Toronto, Interdept Div Crit Care Med, Toronto, ON, Canada
[4] Massachusetts Gen Hosp, Dept Resp Care, Div Pulm & Crit Care Med, Boston, MA 02114 USA
关键词
mechanical ventilation; high-frequency ventilation; protocols; acute respiratory distress syndrome; acute lung injury; ventilator-associated lung injury; acute respiratory failure;
D O I
10.1097/01.CCM.0000269026.40739.2E
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Ventilator settings typically used for high-frequency oscillatory ventilation (HFO) in adults provide acceptable gas exchange but may not take best advantage of its lung-protective aspects. We provide guidelines for HFO in adults with acute respiratory distress syndrome that should optimize the lung-protective characteristics of this ventilation mode. Design: Roundtable discussions, iterative revisions, and consensus. Setting: Five academic medical centers. Patients: Not applicable. Interventions: Participants addressed how to best maintain ventilation through combinations of oscillation pressure amplitude, frequency, and the use of an endotracheal tube cuff leak, and to maintain oxygenation through combinations of recruitment maneuvers, mean airway pressure, and oxygen concentration. The guiding principles were to provide lung protective ventilation by minimizing the size of tidal volumes, and balance the risks and benefits of lung recruitment and distension. Main Results: HFO may provide smaller tidal volumes and more complete lung recruitment than conventional modes. To optimize these features, we recommend use of the maximum pressure-oscillation amplitude coupled with the highest tolerated frequency, targeting a pH of only 7.25-7.35. This will yield a smaller tidal volume than typical HFO settings where frequency is limited to 6 Hz or less and pressure amplitude is submaximal. Lung recruitment can be achieved with the use of recruitment maneuvers, especially during the first several days of HFO. Recruitment may be augmented or sustained with generous mean airway pressures. These may either be chosen from a table of recommended mean airway pressure and oxygen concentration combinations, or individually titrated based on the oxygenation response of each patient. Conclusions: Modification of the goals and tactics of HFO use may better protect against ventilator-associated lung injury. Further clinical trials are needed to compare the effects on patient outcome of the best use of HFO compared to the most protective use of conventional modes in adult acute respiratory distress syndrome.
引用
收藏
页码:1649 / 1654
页数:6
相关论文
共 32 条
[31]   Recruitment maneuvers during lung protective ventilation in acute respiratory distress syndrome [J].
Villagrá, A ;
Ochagavía, A ;
Vatua, S ;
Murias, G ;
Fernández, MDM ;
Aguilar, JL ;
Fernández, R ;
Blanch, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (02) :165-170
[32]   High-frequency oscillatory ventilation - Effects on lung function, mechanics, and airway cytokines in the immature baboon model for neonatal chronic lung disease [J].
Yoder, BA ;
Siler-Khodr, T ;
Winter, VT ;
Coalson, JJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (05) :1867-1876