Assessment of Breast Cancer-Related Arm Lymphedema-Comparison of Physical Measurement Methods and Self-Report

被引:227
作者
Czerniec, S. A. [1 ]
Ward, L. C. [2 ]
Refshauge, K. M. [1 ]
Beith, J. [3 ]
Lee, M. J. [1 ]
York, S. [1 ]
Kilbreath, S. L. [1 ]
机构
[1] Univ Sydney, Fac Hlth Sci, Sydney, NSW 2006, Australia
[2] Univ Queensland, Sch Mol & Microbial Sci, Brisbane, Qld, Australia
[3] Royal Prince Alfred Hosp, Sydney Canc Ctr, Sydney, NSW, Australia
关键词
Bioimpedance spectroscopy; Reliability; Limb circumference; Perometer; BIOELECTRICAL-IMPEDANCE; EARLY-DIAGNOSIS; RELIABILITY; LIMB; BIOIMPEDANCE; AGREEMENT; THERAPY;
D O I
10.3109/07357900902918494
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Purpose: To determine the relationship between physical methods of measuring lymphedema and self-reported swelling, their reliability, and standard error of measurement. Method: Lymphedema in each arm of women with (n = 33) and without (n = 18) unilateral arm lymphedema, secondary to breast cancer was measured by self-report, bioimpedance spectroscopy (BIS), perometer, and the truncated cone method. Results: The physical measurement tools were highly reliable (ICC(2.1): 0.94 to 1.00) with high concordance (r(c): 0.89 to 0.99). Self-report correlated moderately with physical measurements (r = 0.65 to 0.71) and was moderately reliable (ICC(2.1): 0.70). Conclusions: Lymphedema assessment methods are concordant and reliable but not interchangeable.
引用
收藏
页码:54 / 62
页数:9
相关论文
共 38 条
[1]
Armer Jane M., 2005, Lymphatic Research and Biology, V3, P208, DOI 10.1089/lrb.2005.3.208
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
Reliability study of measurements for lymphedema in breast cancer patients [J].
Chen, Yu-Wei ;
Tsai, Han-Ju ;
Hung, Hsiu-Chuan ;
Tsauo, Jau-Yih .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2008, 87 (01) :33-38
[5]
RELIABILITY FOR MULTIPLE FREQUENCY BIOELECTRIC IMPEDANCE [J].
CHUMLEA, WC ;
GUO, SS ;
BELLISARI, A ;
BAUMGARTNER, RN ;
SIERVOGEL, RM .
AMERICAN JOURNAL OF HUMAN BIOLOGY, 1994, 6 (02) :195-202
[6]
Bioelectrical impedance for monitoring the efficacy of lymphoedema treatment programmes [J].
Cornish, BH ;
Bunce, IH ;
Ward, LC ;
Jones, LC ;
Thomas, BJ .
BREAST CANCER RESEARCH AND TREATMENT, 1996, 38 (02) :169-176
[7]
Cornish BH, 2001, LYMPHOLOGY, V34, P2
[8]
Cornish Bruce, 2006, Lymphatic Research and Biology, V4, P47, DOI 10.1089/lrb.2006.4.47
[9]
Deltombe T, 2007, LYMPHOLOGY, V40, P26
[10]
Denegar CR., 1993, J SPORT REHABIL, V2, P35, DOI [10.1123/jsr.2.1.35, DOI 10.1123/JSR.2.1.35]