Novel Assay of Metformin Levels in Patients With Type 2 Diabetes and Varying Levels of Renal Function Clinical recommendations

被引:101
作者
Frid, Anders [1 ]
Sterner, Gunnar N. [2 ]
Londahl, Magnus [3 ]
Wiklander, Clara [3 ]
Cato, Anne [4 ]
Vinge, Ellen [4 ]
Andersson, Anders [4 ]
机构
[1] Univ Hosp MAS, Dept Endocrinol, Malmo, Sweden
[2] Malmo Univ Hosp, Dept Nephrol & Transplantat, Malmo, Sweden
[3] Univ Lund Hosp, Dept Endocrinol, S-22185 Lund, Sweden
[4] Univ Lund Hosp, Dept Clin Chem & Pharmacol, S-22185 Lund, Sweden
关键词
CYSTATIN-C;
D O I
10.2337/dc09-1284
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To study trough levels of metformin in serum and its intra-individual variation in patients using a newly developed assay. RESEARCH DESIGN AND METHODS - Trough serum levels of metformin were measured once using liquid chromatography tandem mass spectrometry (LCMSMS) in 137 type 2 diabetic patients with varying renal function (99 men) and followed repeatedly during 2 months in 20 patients (16 men) with estimated glomerular filtration rate (eGFR) <60 ml/min/1.73 m(2) body surface. RESULTS - Patients with eGFR >60, 30-60, and <30 ml/min/1.73 m(2) had median trough metformin concentrations of 4.5 mu mol/l (range 0.1-20.7, n = 107), 7.71 mu mol/l (0.12-15.15, n = 21), and 8.88 mu mol/l (5.99-18.60, n=9), respectively. The median intra-individual overall coefficient of variation was 29.4% (range 9.8-74.2). CONCLUSIONS - Determination of serum metformin with the LCMSMS technique is useful in patients on metformin treatment. Few patients had values >20 mu mol/l. Metformin measurement is less suitable for close titration.
引用
收藏
页码:1291 / 1293
页数:3
相关论文
共 7 条
[1]   METFORMIN - A REVIEW OF ITS PHARMACOLOGICAL PROPERTIES AND THERAPEUTIC USE IN NON-INSULIN-DEPENDENT DIABETES-MELLITUS [J].
DUNN, CJ ;
PETERS, DH .
DRUGS, 1995, 49 (05) :721-749
[2]   Simple cystatin C-based prediction equations for glomerular filtration rate compared with the modification of diet in renal disease prediction equation for adults and the Schwartz and the Counahan-Barratt prediction equations for children [J].
Grubb, A ;
Nyman, U ;
Björk, J ;
Lindström, V ;
Rippe, B ;
Sterner, G ;
Christensson, A .
CLINICAL CHEMISTRY, 2005, 51 (08) :1420-1431
[3]   Quantification of Methylmalonic Acid in Human Plasma with Hydrophilic Interaction Liquid Chromatography Separation and Mass Spectrometric Detection [J].
Lakso, Hans-Ake ;
Appelblad, Patrik ;
Schneede, Jorn .
CLINICAL CHEMISTRY, 2008, 54 (12) :2028-2035
[4]   Serial measurements of cystatin C are more accurate than creatinine-based methods in detecting declining renal function in type 1 diabetes [J].
Premaratne, Erosha ;
Macisaac, Richard J. ;
Finch, Sue ;
Panagiotopoulos, Sianna ;
Ekinci, Elif ;
Jerums, George .
DIABETES CARE, 2008, 31 (05) :971-973
[5]   Clinical pharmacokinetics of metformin [J].
Scheen, AJ .
CLINICAL PHARMACOKINETICS, 1996, 30 (05) :359-371
[6]   Establishing pragmatic estimated GFR thresholds to guide metformin prescribing [J].
Shaw, J. S. ;
Wilmot, R. L. ;
Kilpatrick, E. S. .
DIABETIC MEDICINE, 2007, 24 (10) :1160-1163
[7]   Liquid chromatography-tandem mass spectrometry - Application in the clinical laboratory [J].
Vogeser, M .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (02) :117-126