Liquid chromatography-tandem mass spectrometry - Application in the clinical laboratory

被引:32
作者
Vogeser, M [1 ]
机构
[1] Univ Munich, Inst Clin Chem, Munich, Germany
关键词
liquid chromatography-tandem mass spectrometry; application; clinical laboratory;
D O I
10.1515/CCLM.2003.020
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
This review provides a concise survey of liquid chromatography tandem mass spectrometry (LCTMS) as an emerging technology in clinical chemistry. The combination of two mass spectrometers with an interposed collision cell characterizes LCTMS as an analytical technology on its own and not just as a more specific detector for HPLC compared with conventional techniques. In LCTMS, liquid chromatography is rather used for sample preparation but not for complete resolution of compounds of interest. The instrument technology of LCTMS is complex and comparatively expensive; however, in routine use, methods are far more rugged compared to conventional chromatographic techniques and enable highthroughput analyses with very limited manual handling steps. Moreover, compared to both gas chromatographymass spectrometry (GCMS) and conventional HPLC techniques, LCTMS is substantially more versatile with respect to the spectrum of analyzable compounds. For these reasons it is likely that LCTMS will gain far more widespread use in the clinical laboratory than HPLC and GCMS ever did. In this article, the key features of LCTMS are described, method development is explained, typical fields of application are discussed, and personal experiences are related.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 24 条
[1]   Application of tandem mass spectrometry to biochemical genetics and newborn screening [J].
Carpenter, KH ;
Wiley, V .
CLINICA CHIMICA ACTA, 2002, 322 (1-2) :1-10
[2]   Validation of the phenylalanine/tyrosine ratio determined by tandem mass spectrometry:: Sensitive newborn screening for phenylketonuria [J].
Ceglarek, U ;
Müller, P ;
Stach, B ;
Bührdel, P ;
Thiery, J ;
Kiess, W .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (07) :693-697
[3]  
Ford RE, 2001, CLIN CHEM, V47, P1627
[4]  
Jemal M, 2000, BIOMED CHROMATOGR, V14, P422, DOI 10.1002/1099-0801(200010)14:6<422::AID-BMC25>3.0.CO
[5]  
2-I
[6]   Population pharmacokinetic and pharmacodynamic analysis of ribavirin in patients with chronic hepatitis C [J].
Jen, JF ;
Glue, P ;
Gupta, S ;
Zambas, D ;
Hajian, G .
THERAPEUTIC DRUG MONITORING, 2000, 22 (05) :555-565
[7]  
Kushnir MM, 2002, CLIN CHEM, V48, P323
[8]  
Kushnir MM, 2001, CLIN CHEM, V47, P1993
[9]  
LANGERWERF FM, 2000, TRENDS ANAL CHEM, V19, P418
[10]   Quantitative analysis by liquid chromatography tandem mass spectrometry of deuterium-labeled and unlabeled vitamin E in biological samples [J].
Lauridsen, C ;
Leonard, SW ;
Griffin, DA ;
Liebler, DC ;
McClure, TD ;
Traber, MG .