Application of real-time quantitative PCR for the detection of selected bacterial pathogens during municipal wastewater treatment

被引:220
作者
Shannon, K. E.
Lee, D.-Y.
Trevors, J. T.
Beaudette, L. A.
机构
[1] Environm Canada, Environm Technol Ctr, Sci & Technol Branch, Ottawa, ON K1A 0H3, Canada
[2] Environm Canada, Aquat Ecosyst Management Res Div, Sci & Technol Branch, Burlington, ON L7R 4A6, Canada
[3] Univ Guelph, Dept Environm Biol, Guelph, ON N1G 2W1, Canada
关键词
detection; disease; enumeration; environment; microorganisms; pathogens; public health; real-time quantitative PCR; wastewater; water;
D O I
10.1016/j.scitotenv.2007.02.039
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Bacteria were detected at five stages of municipal wastewater treatment using TaqMan((R)) real-time quantitative PCR (qPCR). Thirteen probe and primer sets were tested for diverse pathogens that may be present in wastewater, including Aeromonas hydrophila, Bacillus cereus, Clostridium perfringens, Enterococcus Jaecalis, Escherichia coli, E. coli O157:117, Helicobacter pylori, Klebsiella pneumoniae, Legionella pneumophila, Listeria monocytogenes, Pseudomonas aeruginosa, Salmonella sp., and Staphylococcus aureus. The sensitivity of the assay was 100 fg of genomic DNA (=22 gene copies), based on a standard curve generated using A. hydrophila purified DNA. Samples from five stages of wastewater treatment were collected, including raw wastewater, primary effluents, mixed liquor, waste activated sludge and final effluents. In duplicate samples, E. coli, K. pneumoniae, C. perfringens and E. Jaecalis were detected throughout the wastewater process, and their numbers decreased by 3.52-3.98, 4.23-4.33, 3.15-3.39, and 3.24 orders of magnitude respectively, between the raw wastewater and final effluent stage. This qPCR method was effective for the detection of pathogens in wastewater and confirmed that the risk of exposure to pathogens in the wastewater discharge was well within the Environment Canada guidelines. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 129
页数:9
相关论文
共 23 条
[1]   Optimization of PCR-based methods for rapid detection of Campylobacter jejuni, Campylobacter coli and Yersinia enterocolitica serovar 0:3 in wastewater samples [J].
Alexandrino, M ;
Grohmann, E ;
Szewzyk, U .
WATER RESEARCH, 2004, 38 (05) :1340-1346
[2]  
[Anonymous], 1994, WASTEWATER MICROBIOL
[3]  
*BRUC GRY OW SOUND, 2000, INV REP WALK OUTB WA
[4]   Detecting and genotyping Escherichia coli O157:H7 using multiplexed PCR and nucleic acid microarrays [J].
Call, DR ;
Brockman, FJ ;
Chandler, DP .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2001, 67 (1-2) :71-80
[5]   Presence of β-lactamase gene TEM-1 DNA sequence in commercial Taq DNA polymerase [J].
Chiang, CS ;
Liu, CP ;
Weng, LC ;
Wang, NY .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (01) :530-531
[6]   Construction of a physical and preliminary genetic map of Aeromonas hydrophila JMP636 [J].
Dodd, HN ;
Pemberton, JM .
MICROBIOLOGY-SGM, 1998, 144 :3087-3096
[7]   Real-time PCR for quantification of Giardia and Cryptosporidium in environmental water samples and sewage [J].
Guy, RA ;
Payment, P ;
Krull, UJ ;
Horgen, PA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2003, 69 (09) :5178-5185
[8]  
HU CJ, 1995, WATER SCI TECHNOL, V31, P303, DOI 10.1016/0273-1223(95)00284-T
[9]   IDENTIFICATION AND ELIMINATION OF DNA-SEQUENCES IN TAQ DNA-POLYMERASE [J].
HUGHES, MS ;
BECK, LA ;
SKUCE, RA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (08) :2007-2008
[10]   Multiplex fluorogenic real-time PCR for detection and quantification of Escherichia coli O157:H7 in dairy wastewater wetlands [J].
Ibekwe, AM ;
Watt, PM ;
Grieve, CM ;
Sharma, VK ;
Lyons, SR .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2002, 68 (10) :4853-4862