Manganese detection in marine sediments:: anodic vs. cathodic stripping voltammetry

被引:64
作者
Banks, CE
Kruusma, J
Moore, RR
Tomcík, P
Peters, J
Davis, J
Komorsky-Lovric, S
Compton, RG
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[2] Univ Agr, Environm Protect Inst Estonian, EE-51003 Tartu, Estonia
[3] Univ Surrey, Sch Biomed & Mol Sci, Dept Chem, Guildford GU2 7XH, Surrey, England
[4] Rudjer Boskovic Inst, Ctr Marine & Environm Res, Zagreb, Croatia
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
manganese; anodic stripping voltammetry; cathodic stripping voltammetry; bismuth-film electrodes; boron-doped diamond electrodes; marine sediments;
D O I
10.1016/j.talanta.2004.06.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three different electroanalytical techniques for the detection of manganese in marine sediments are evaluated. The anodic stripping voltammetry of manganese at an in situ bismuth-film-modified boron-doped diamond electrode and cathodic stripping voltammetry at a carbon paste electrode are shown to lack the required sensitivity and reproducibility whereas cathodic stripping voltammetry at a bare boron-doped diamond electrode is shown to be reliable and selective with a limit of detection, from applying a 60 s accumulation period of 7.4 x 10(-7) M and a sensitivity of 0.24 A M-1. The method was used to evaluate the manganese content of marine sediments taken from Sibenik. Croatia. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:423 / 429
页数:7
相关论文
共 32 条
[1]   Ultrasonically enhanced voltammetric analysis and applications: An overview [J].
Banks, CE ;
Compton, RG .
ELECTROANALYSIS, 2003, 15 (5-6) :329-346
[2]  
Banks CE, 2003, CHEM ANAL-WARSAW, V48, P159
[3]   Formation of some manganese minerals from ferromanganese factory waste disposed in the Krka River Estuary [J].
Bilinski, H ;
Kwokal, Z ;
Branica, M .
WATER RESEARCH, 1996, 30 (03) :495-500
[4]   VOLTAMMETRIC STUDIES AND STRIPPING VOLTAMMETRY OF MN(II) AT THE WALL-JET RING-DISC ELECTRODE [J].
BRETT, CMA ;
NETO, MMPM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 258 (02) :345-355
[5]  
Dijck G. V., 1971, ANAL CHIM ACTA, V54, P475
[6]   Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes [J].
Filipe, OMS ;
Brett, CMA .
TALANTA, 2003, 61 (05) :643-650
[7]  
Flechsig GU, 2002, ELECTROANAL, V14, P192, DOI 10.1002/1521-4109(200202)14:3<192::AID-ELAN192>3.0.CO
[8]  
2-6
[9]  
GADD GM, 1978, MICROBIAL ECOL, V4, P303, DOI 10.1007/BF02013274
[10]   Study of interferences in graphite furnace atomic absorption spectrometry by means of experimental design [J].
Grotti, M ;
Magi, E ;
Leardi, R .
ANALYTICA CHIMICA ACTA, 1996, 327 (01) :47-51