Manganese detection in marine sediments:: anodic vs. cathodic stripping voltammetry

被引:64
作者
Banks, CE
Kruusma, J
Moore, RR
Tomcík, P
Peters, J
Davis, J
Komorsky-Lovric, S
Compton, RG
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[2] Univ Agr, Environm Protect Inst Estonian, EE-51003 Tartu, Estonia
[3] Univ Surrey, Sch Biomed & Mol Sci, Dept Chem, Guildford GU2 7XH, Surrey, England
[4] Rudjer Boskovic Inst, Ctr Marine & Environm Res, Zagreb, Croatia
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
manganese; anodic stripping voltammetry; cathodic stripping voltammetry; bismuth-film electrodes; boron-doped diamond electrodes; marine sediments;
D O I
10.1016/j.talanta.2004.06.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three different electroanalytical techniques for the detection of manganese in marine sediments are evaluated. The anodic stripping voltammetry of manganese at an in situ bismuth-film-modified boron-doped diamond electrode and cathodic stripping voltammetry at a carbon paste electrode are shown to lack the required sensitivity and reproducibility whereas cathodic stripping voltammetry at a bare boron-doped diamond electrode is shown to be reliable and selective with a limit of detection, from applying a 60 s accumulation period of 7.4 x 10(-7) M and a sensitivity of 0.24 A M-1. The method was used to evaluate the manganese content of marine sediments taken from Sibenik. Croatia. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:423 / 429
页数:7
相关论文
共 32 条
[21]  
REHM BHJ, 1986, MICROBIAL DEGRADATIO, V8, P408
[22]   Flow-injection preconcentration and electrothermal atomic absorption spectrometry determination of manganese in seawater [J].
Sarzanini, C ;
Abollino, O ;
Mentasti, E .
ANALYTICA CHIMICA ACTA, 2001, 435 (02) :343-350
[23]   Sono-cathodic stripping voltammetry of manganese at a polished boron-doped diamond electrode: application to the determination of manganese in instant tea [J].
Saterlay, AJ ;
Foord, JS ;
Compton, RG .
ANALYST, 1999, 124 (12) :1791-1796
[24]   PHOTO-REDUCTION OF MANGANESE OXIDES IN SEAWATER AND ITS GEOCHEMICAL AND BIOLOGICAL IMPLICATIONS [J].
SUNDA, WG ;
HUNTSMAN, SA ;
HARVEY, GR .
NATURE, 1983, 301 (5897) :234-236
[25]   A self-catalytic carbon paste electrode for the detection of vitamin B12 [J].
Tomcik, P ;
Banks, CE ;
Davies, TJ ;
Compton, RG .
ANALYTICAL CHEMISTRY, 2004, 76 (01) :161-165
[26]  
Vytras K, 2002, ELECTROANAL, V14, P1359, DOI 10.1002/1521-4109(200211)14:19/20<1359::AID-ELAN1359>3.0.CO
[27]  
2-P
[28]   Bismuth-coated carbon electrodes for anodic stripping voltammetry [J].
Wang, J ;
Lu, JM ;
Hocevar, SB ;
Farias, PAM ;
Ogorevc, B .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3218-3222
[29]   Insights into the anodic stripping voltammetric behavior of bismuth film electrodes [J].
Wang, J ;
Lu, JM ;
Anik, Ü ;
Hocevar, SB ;
Ogorevc, B .
ANALYTICA CHIMICA ACTA, 2001, 434 (01) :29-34
[30]   Bismuth film electrodes for adsorptive stripping voltammetry of trace nickel [J].
Wang, J ;
Lu, JM .
ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (06) :390-393