In vivo kinematic measurement during laparoscopic cholecystectomy

被引:10
作者
Rasmus, M
Riener, R
Reiter, S
Schneider, A
Feussner, H
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Minimally Invas Therapy & Intervent Res Grp, D-81675 Munich, Germany
[2] Tech Univ Munich, Inst Automat Control Engn, D-81675 Munich, Germany
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2004年 / 18卷 / 11期
关键词
robotics; kinematic measurement; motion analysis; laparoscopic surgery; in vivo measurements; computer-assisted surgery;
D O I
10.1007/s00464-003-9196-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Despite the rapid development of computer-assisted surgery, studies on kinematic measurement for surgical innovation are rare. This study describes a system for kinematic measurement in real operating theater environments. Six laparoscopic cholecystectomies were recorded and analyzed. In addition to a demonstration of the feasibility of the method, basis data for the development of an actuated laparoscopic camera holder are evaluated. Methods: The positions of four receivers were recorded by an electromagnetic motion acquisition system. Analysis of the data was performed postoperatively with matlab. Parameters such as coordinates, velocities, angles, angular velocities, workspaces in typical phases of an operation, and subareas of the coordinate ranges were computed. Results: The workspace during the operation in situ before (II) and after (V) removal of the gallbladder at the upper camera end was as follows: (X, Y, Z; given in cm): II: 65.5 . 42.7 . 27.3 (subarea 90% = 8.3 . 14.0 . 6.3); V: 57.4 . 33.3 . 26.2, (90% = 10.3 . 16.5 . 7.9). Workspaces at the lower camera end were smaller: II: 14.8 . 9.7 . 15.4; (90% = 3.5 . 3.1 . 4.3). During these operation phases, velocities up to 82.9 cm/s were documented. Most of the measured velocities were much smaller. The camera-tilt-angles in left/right (alphax) and head/ feet (alphay) direction were as follows: alphax: -69degrees to + 69degrees and alphay: -74degrees to + 48degrees. Conclusion: This study demonstrates the feasibility of real-time kinematic measurement in the operation environment. The information might be of future value not only as basis data for the development of camera holders, but also for further investigations on robotics, ergonomics, and simulation.
引用
收藏
页码:1649 / 1656
页数:8
相关论文
共 11 条
[1]  
CAO C, 1996, P ASME DYN SYST CONT, V58, P583
[2]  
DETTER B, 1995, GRUNDLAGEN LAPAROSKO
[3]   In vivo measurement of surgical gestures [J].
Dubois, P ;
Thommen, Q ;
Jambon, AC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (01) :49-54
[4]   Rocker handle for endoscopic needle drivers - Technical and ergonomic evaluation by infrared motion analysis system [J].
Emam, TA ;
Frank, TG ;
Hanna, GB ;
Stockham, G ;
Cuschieri, A .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (07) :658-661
[5]   Influence of handle design on the surgeon's upper limb movements, muscle recruitment, and fatigue during endoscopic suturing [J].
Emam, TA ;
Frank, TG ;
Hanna, GB ;
Cuschieri, A .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2001, 15 (07) :667-672
[6]   A comparison of the accuracy of an electromagnetic and a hybrid ultrasound-inertia position tracking system [J].
Kindratenko, V .
PRESENCE-VIRTUAL AND AUGMENTED REALITY, 2001, 10 (06) :657-663
[7]  
MacKenzie CL, 2001, MINIM INVASIV THER, V10, P121
[8]  
PAYANDEH S, 2002, DEFINING METRICES AS, P334
[9]   Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery [J].
Person, JG ;
Hodgson, AJ ;
Nagy, AG .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (09) :997-1003
[10]   Acquisition of arm and instrument movements during laparoscopic interventions [J].
Riener, R ;
Reiter, S ;
Rasmus, M ;
Wetzel, D ;
Feussner, H .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2003, 12 (05) :235-240