An improved statistical methodology to estimate and analyze impedances and transfer functions

被引:4
作者
CurranEverett, D [1 ]
Zhang, YM [1 ]
Jones, MD [1 ]
Jones, RH [1 ]
机构
[1] UNIV COLORADO,HLTH SCI CTR,SCH MED,DEPT PREVENT MED & BIOMETR,DENVER,CO 80262
关键词
discrete Fourier transform; frequency-domain regression; frequency-response function; mixed-effects model; spectral analysis;
D O I
10.1152/jappl.1997.83.6.2146
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Estimating the mathematical relationship between pulsatile time series (e.g., pressure and flow) is an effective technique for studying dynamic systems. The frequency-domain relationship between time series, often calculated as an impedance (pressure/flow), is known more generally as a frequency-response or transfer function (output/input). Current statistical methods for transfer function analysis I) assume erroneously that repeated observations on a subject are independent, 2) have limited statistical value and power, or 3) are restricted to use in single subjects rather than in an entire sample. This paper develops a regression model for transfer function analysis that corrects each of these deficiencies. Spectral densities of the input and output time series and the cross-spectral density between them are first estimated from discrete Fourier transforms and then used to obtain regression estimates of the transfer function. Statistical comparisons of the transfer function estimates use a test statistic that is distributed as chi(2). Confidence intervals for amplitude and phase can also be calculated. By correctly modeling repeated observations on each subject, this improved statistical approach to transfer function estimation and analysis permits the simultaneous analysis of data from all subjects in a sample, improves the power of the transfer :Function model, and has broad relevance to the study of dynamic physiological systems.
引用
收藏
页码:2146 / 2157
页数:12
相关论文
共 49 条
[31]   PULMONARY MECHANICS BY SPECTRAL ANALYSIS OF FORCED RANDOM NOISE [J].
MICHAELSON, ED ;
GRASSMAN, ED ;
PETERS, WR .
JOURNAL OF CLINICAL INVESTIGATION, 1975, 56 (05) :1210-1230
[32]  
Milnor WR., 1989, HEMODYNAMICS
[33]  
MODARRESZADEH M, 1995, J APPL PHYSIOL, V79, P1071, DOI 10.1152/jappl.1995.79.4.1071
[34]   INPUT IMPEDANCE OF THE PULMONARY ARTERIAL SYSTEM IN NORMAL MAN - EFFECTS OF RESPIRATION AND COMPARISON TO SYSTEMIC IMPEDANCE [J].
MURGO, JP ;
WESTERHOF, N .
CIRCULATION RESEARCH, 1984, 54 (06) :666-673
[35]  
Nichols W.W., 1990, MCDONALDS BLOOD FLOW
[36]   INPUT IMPEDANCE OF SYSTEMIC CIRCULATION [J].
OROURKE, MF ;
TAYLOR, MG .
CIRCULATION RESEARCH, 1967, 20 (04) :365-&
[37]   MECHANICAL FACTORS IN DISTRIBUTION OF PULMONARY VENTILATION [J].
OTIS, AB ;
MCKERROW, CB ;
BARTLETT, RA ;
MEAD, J ;
MCILROY, MB ;
SELVERSTONE, NJ ;
RADFORD, EP .
JOURNAL OF APPLIED PHYSIOLOGY, 1956, 8 (04) :427-443
[38]  
PRIESTLEY MB, 1981, SPECTRAL ANAL TIME S, V1
[39]   STATISTICAL PROPERTIES OF PULSATILE PRESSURE AND FLOW IN THE FEMORAL ARTERY OF THE DOG [J].
RANDALL, JE .
CIRCULATION RESEARCH, 1958, 6 (06) :689-698
[40]  
Rodarte J R., 1986, Handbook of Physiology, section 3: The Respiratory System, P131