Performances of miniature microstrip detectors made on oxygen enriched p-type substrates after very high proton irradiation

被引:58
作者
Casse, G [1 ]
Allport, PP [1 ]
Garcia, SMI [1 ]
Lozano, M [1 ]
Turner, PR [1 ]
机构
[1] Univ Liverpool, Dept Phys, Oliver Lodge Lab, Liverpool L69 3BX, Merseyside, England
关键词
radiation damage; silicon microstrip detectors; charge collection efficiency;
D O I
10.1016/j.nima.2004.07.153
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon microstrip detectors with n-type implant read-out strips on FZ p-type bulk (n-in-p) show superior charge collection properties, after heavy irradiation, to the more standard p-strips in n-type silicon (p-in-n). It is also well established that oxygen-enriched n-type silicon substrates show better performance, in terms of degradation of the full depletion voltage after charged hadron irradiation, than the standard FZ silicon used for high energy physics detectors. Silicon microstrip detectors combining both the advantages of oxygenation and of n-strip read-out (n-in-n) have achieved high radiation tolerance to charged hadrons. The manufacturing of n-in-n detectors though requires double-sided processing, resulting in more complicated and expensive devices than standard p-in-n. A cheaper single-sided option, that still combines these advantages, is to use n-in-p devices. P-type FZ wafers have been oxygen-enriched by high temperature diffusion from an oxide layer and succesfully used to process miniature (1 x 1 cm(2)) microstrip detectors. These detectors have been irradiated with 24 GeV/c protons in the CERN/PS T7 irradiation area up to similar to7.5 x 10(15) cm(-2). We report results with these irradiated detectors in terms of the charge collection efficiency as a function of the applied bias voltage. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:362 / 365
页数:4
相关论文
共 7 条
[1]   Annealing effects on irradiated n+n silicon detectors [J].
Allport, PP ;
Booth, PSL ;
Green, C ;
Greenall, A ;
Jackson, JN ;
Jones, TJ ;
Richardson, JD ;
Garcia, SMI ;
Smith, NA ;
Turner, PR ;
Wormald, MP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 420 (03) :473-480
[2]   Charge collection and charge sharing in heavily irradiated n-side read-out silicon microstrip detectors [J].
Casse, G ;
Allport, PP ;
Biagi, SF ;
Bowcock, TJV ;
Greenall, A ;
Turner, PR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (1-2) :112-117
[3]   Introduction of high oxygen concentrations into silicon wafers by high-temperature diffusion [J].
Casse, G ;
Glaser, M ;
Lemeilleur, F ;
Ruzin, A ;
Wegrzecki, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 438 (2-3) :429-432
[4]  
*CERN LHCC, 1999, 2000009 CERN LHCC
[5]   New irradiation zones at the CERN-PS [J].
Glaser, M ;
Durieu, L ;
Lemeilleur, F ;
Tavlet, M ;
Leroy, C ;
Roy, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 426 (01) :72-77
[6]  
Kaplon J., 1997, IEEE T NUCL SCI, VNS-44, P298
[7]  
OSHUGI T, 1994, NUCL INSTRUM METH A, V342, P22