The delivery of intensity modulated radiotherapy to the breast using multiple static fields

被引:94
作者
Evans, PM
Donovan, EM
Partridge, M
Childs, PJ
Convery, DJ
Eagle, S
Hansen, VN
Suter, BL
Yarnold, JR
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Dept Radiotherapy, Sutton SM2 5PT, Surrey, England
关键词
breast radiotherapy; conformal radiotherapy; intensity modulated beams; multileaf collimators;
D O I
10.1016/S0167-8140(00)00263-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To develop a method of using a multileaf collimator (MLC) to deliver intensity modulated radiotherapy (IMRT) for tangential breast fields, using an MLC to deliver a set of multiple static fields (MSFs). Materials and methods: An electronic portal imaging device (EPID) is used to obtain thickness maps of medial and lateral tangential breast fields. From these IMRT deliveries are designed to minimize the volume of breast above 105% of prescribed dose. The deliveries are universally-wedged beams augmented with a set of low dose shaped irradiations. Dosimetric and planning QA of this method has been compared with the standard, wedged treatment and the corresponding treatment using physical compensators. Several options for delivering the MSF treatment are presented. Results: The MSF technique was found to be superior to the standard technique (P value = 0.002) and comparable with the compensated technique. Both IMRT methods reduced the volume of breast above 105% dose from a mean value of 12.0% of the total breast volume to similar to2.8% of the total breast volume. Conclusions: This MSF method may be used to reduce the high dose volume in tangential breast irradiation significantly. This may have consequences for long-term side effects, particularly cosmesis. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:79 / 89
页数:11
相关论文
共 36 条
[11]   Practical implementation of compensators in breast radiotherapy [J].
Evans, PM ;
Donovan, EM ;
Fenton, N ;
Hansen, VN ;
Moore, I ;
Partridge, M ;
Reise, S ;
Suter, B ;
Symonds-Tayler, JRN ;
Yarnold, JR .
RADIOTHERAPY AND ONCOLOGY, 1998, 49 (03) :255-265
[12]   LUMPECTOMY COMPARED WITH LUMPECTOMY AND RADIATION-THERAPY FOR THE TREATMENT OF INTRADUCTAL BREAST-CANCER [J].
FISHER, B ;
COSTANTINO, J ;
REDMOND, C ;
FISHER, E ;
MARGOLESE, R ;
DIMITROV, N ;
WOLMARK, N ;
WICKERHAM, DL ;
DEUTSCH, M ;
ORE, L ;
MAMOUNAS, E ;
POLLER, W ;
KAVANAH, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 328 (22) :1581-1586
[13]   8-YEAR RESULTS OF A RANDOMIZED CLINICAL-TRIAL COMPARING TOTAL MASTECTOMY AND LUMPECTOMY WITH OR WITHOUT IRRADIATION IN THE TREATMENT OF BREAST-CANCER [J].
FISHER, B ;
REDMOND, C ;
POISSON, R ;
MARGOLESE, R ;
WOLMARK, N ;
WICKERHAM, L ;
FISHER, E ;
DEUTSCH, M ;
CAPLAN, R ;
PILCH, Y ;
GLASS, A ;
SHIBATA, H ;
LERNER, H ;
TERZ, J ;
SIDOROVICH, L .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (13) :822-828
[14]   Prediction of excess risk of long-term cardiac mortality after radiotherapy of stage I breast cancer [J].
Gagliardi, G ;
Lax, I ;
Söderström, S ;
Gyenes, G ;
Rutqvist, LE .
RADIOTHERAPY AND ONCOLOGY, 1998, 46 (01) :63-71
[15]  
GOITEIN M, 1982, PROGR MED RAD PHYSIC, V1, P195
[16]   Dosimetric evaluation of compensation in radiotherapy of the breast: MLC intensity modulation and physical compensators [J].
Hansen, VN ;
Evans, PM ;
Shentall, GS ;
Helyer, SJ ;
Yarnold, JR ;
Swindell, W .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (03) :249-256
[17]   Quality assurance of the dose delivered by small radiation segments [J].
Hansen, VN ;
Evans, PM ;
Budgell, GJ ;
Mott, JHL ;
Williams, PC ;
Brugmans, MJP ;
Wittkamper, FW ;
Mijnheer, BJ ;
Brown, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (09) :2665-2675
[18]  
HONG L, 1999, INT J RADIAT ONCOL, V44, P55
[19]   Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy [J].
LoSasso, T ;
Chui, CS ;
Ling, CC .
MEDICAL PHYSICS, 1998, 25 (10) :1919-1927
[20]  
LU HM, 1998, INT J RADIAT ONCOL, V42, P247