6-Oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl)fluorescein as a new fluorescent labeling reagent for aliphatic amines in environmental and food samples using high-performance liquid chromatography

被引:63
作者
Cao, LW [1 ]
Wang, H [1 ]
Li, JS [1 ]
Zhang, HS [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
6-Oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl)fluorescein (SAMF); aliphatic amines; derivatization;
D O I
10.1016/j.chroma.2004.11.093
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
6-Oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl)fluorescein (SAMF), a new fluorescein-based amine-reactive fluorescent probe was well designed, synthesized and used as a pre-column derivatizing reagent for the determination of aliphatic amines in HPLC. It exhibited relatively pH-independent fluorescence (pH 4-9) and excellent photostability. The derivatization was performed at room temperature in 6 min. On a C-18 column, the derivatives of SAMF with eight aliphatic amines were baseline separated in 28 min with a mobile phase of methanol-water (57:43, v/v) containing 10 mmol l(-1) pH 5.0, H(3)Cit(3)-NaOH buffer. With fluorescent detection at lambda(ex)/lambda(em) = 484/516 nm, the detection limit could reach 2-320 fmol (signal-to-noise = 3), which was equivalent to or better than the detection limits obtained from other analytical methods of aliphatic amines. The proposed method has been applied to the determination of the aliphatic amines in environmental and food samples such as lake water, red wine, white wine, and cheese with satisfying recoveries varying from 95 to 106%. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:143 / 151
页数:9
相关论文
共 32 条
[21]  
MATCHETT WH, 1997, J LIQ CHROMATOGR R T, V20, P249
[22]   IMPROVEMENT OF LASER-INDUCED FLUORESCENCE DETECTION OF AMINO-ACIDS IN CAPILLARY ZONE ELECTROPHORESIS [J].
MATTUSCH, J ;
DITTRICH, K .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :279-285
[23]  
RICHARD P, 2003, HDB FLUORESCENT PROB
[24]   Separation of biogenic amines by micellar electrokinetic chromatography [J].
Rodriguez, I ;
Lee, HK ;
Li, SFY .
JOURNAL OF CHROMATOGRAPHY A, 1996, 745 (1-2) :255-262
[25]   DETERMINATION OF ALIPHATIC PRIMARY AND SECONDARY-AMINES AND POLYAMINES IN AIR BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
SIMON, P ;
LEMACON, C .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :480-484
[26]  
SimonSarkadi L, 1997, JPC-J PLANAR CHROMAT, V10, P59
[27]  
*US EPA, SW846 US EPA B, V1
[28]   Liquid chromatographic determination of aliphatic amines in water using solid support assisted derivatization with 9-fluorenylmethyl chloroformate [J].
Verdú-Andrés, J ;
Campíns-Falcó, P ;
Herráez-Hernández, R .
CHROMATOGRAPHIA, 2002, 55 (3-4) :129-134
[29]   N-hydroxysuccinimidyl fluorescein-O-acetate as a highly fluorescent derivatizing reagent for aliphatic amines in liquid chromatography [J].
Wang, H ;
Li, J ;
Liu, X ;
Zhang, HS .
ANALYTICA CHIMICA ACTA, 2000, 423 (01) :77-83
[30]   N-hydroxysuccinimidyl fluorescein-O-acetate as a fluorescent derivatizing reagent for catecholamines in liquid chromatography [J].
Wang, H ;
Li, J ;
Liu, X ;
Yang, TX ;
Zhang, HS .
ANALYTICAL BIOCHEMISTRY, 2000, 281 (01) :15-20