Development of a real-time Staphylococcus aureus and MRSA (SAM-) PCR for routine blood culture

被引:78
作者
Thomas, L. C.
Gidding, H. F.
Ginn, A. N.
Olma, T.
Iredell, J. [1 ]
机构
[1] Univ Sydney, Ctr Infect Dis & Microbiol Publ Hlth, Sydney, NSW 2006, Australia
[2] Westmead Hosp, Inst Clin Pathol & Med Res, Westmead, NSW 2145, Australia
关键词
real-time PCR; gram positive; staphylococcus; PCR inhibition;
D O I
10.1016/j.mimet.2006.09.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The notification of "Gram-positive cocci, possibly staphylococcus" in a blood culture drawn from a seriously ill patient is responsible for a large amount of vancomycin prescribing in institutions where methicillin-resistant Staphylococcus aureus (MRSA) is an important cause of bacteraemia. A duplex real-time TaqMan polymerase chain reaction targeting the species-specific nuc gene, and the mecA gene encoding methicillin-resistance, was developed as a tool for rapid identification and detection of S. aureus and methicillin-resistance, and optimised for immediate as-needs testing. Three different DNA extraction methods achieved varying DNA quality, with PCR inhibition the main problem. Serial blood cultures (n=120) identified as possible staphylococci on Gram stain from our clinical laboratory were examined. There was one false negative result for a methicillin-resistant Staphylococcus epidermidis, which was positive on repeat testing, and one false negative result due to DNA extraction failure for MRSA from peritoneal dialysate inoculated into blood culture medium. Sensitivity and specificity of 97% and 100%, respectively, were obtained for mecA; and sensitivity and specificity of 98% and 100%, respectively, for nuc. Detection of slow-growing coagulase-negative staphylococci as co-infecting strains may be reduced. The assay quickly and reliably identified S. aureus in mixed infection, and identified methicillin resistance in both S. epidermidis and S. aureus strains. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 48 条
[31]   Increasing threat of Gram-positive bacterial infections in the intensive care unit setting [J].
McGowan, JE .
CRITICAL CARE MEDICINE, 2001, 29 (04) :N69-N74
[32]   IDENTIFICATION OF METHICILLIN-RESISTANT STRAINS OF STAPHYLOCOCCI BY POLYMERASE CHAIN-REACTION [J].
MURAKAMI, K ;
MINAMIDE, W ;
WADA, K ;
NAKAMURA, E ;
TERAOKA, H ;
WATANABE, S .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (10) :2240-2244
[33]   Emergence of heteroresistant vancomycin-intermediate Staphylococcus aureus (hVISA) infection in Western Australia [J].
Murray, RJ ;
Sieunarine, K ;
Ward, PB ;
Pearman, JW .
MEDICAL JOURNAL OF AUSTRALIA, 2004, 181 (04) :227-228
[34]   Rapid detection and identification of Staphylococcus aureus from blood culture specimens using real-time fluorescence PCR [J].
Palomares, C ;
Torres, MJ ;
Torres, A ;
Aznar, J ;
Palomares, JC .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2003, 45 (03) :183-189
[35]   Real-time PCR can rapidly detect methicillin-susceptible and methicillin-resistant Staphylococcus aureus directly from positive blood culture bottles [J].
Paule, SM ;
Pasquariello, AC ;
Thomson, RB ;
Kaul, KL ;
Peterson, LR .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2005, 124 (03) :404-407
[36]   A rapid (20 h) solid screening medium for detecting methicillin-resistant Staphylococcus aureus [J].
Perry, PL ;
Coombs, GW ;
Boehm, JD ;
Pearman, JW .
JOURNAL OF HOSPITAL INFECTION, 1998, 40 (01) :67-72
[37]   Direct identification of bacteria from positive blood cultures by amplification and sequencing of the 16S rRNA gene: Evaluation of BACTEC 9240 instrument true-positive and false-positive results [J].
Qian, QF ;
Tang, YW ;
Kolbert, CP ;
Torgerson, CA ;
Hughes, JG ;
Vetter, EA ;
Harmsen, WS ;
Montgomery, SO ;
Cockerill, FR ;
Persing, DH .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (10) :3578-3582
[38]  
Reischl U, 2000, J CLIN MICROBIOL, V38, P2429
[39]   Reduced PCR sensitivity due to impaired DNA recovery with the MagNA pure LC total nucleic acid isolation kit [J].
Schuurman, T ;
van Breda, A ;
de Boer, R ;
Kooistra-Smid, M ;
Beld, M ;
Savelkoul, P ;
Boom, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (09) :4616-4622
[40]   Rapid identification of Staphylococcus aureus and the mecA gene from BacT/ALERT blood culture bottles by using the LightCycler system [J].
Shrestha, NK ;
Tuohy, MJ ;
Hall, GS ;
Isada, CM ;
Procop, GW .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (07) :2659-2661