Polarographic behaviour of Aceclofenac, Tenoxicam and Droxicam in a methanol-water mixture

被引:10
作者
Acuña, JA [1 ]
Vázquez, MD [1 ]
Tascón, ML [1 ]
Sánchez-Batanero, P [1 ]
机构
[1] Univ Valladolid, Fac Sci, Dept Analyt Chem, Valladolid, Spain
关键词
Aceclofenac; Tenoxicam; Droxicam; tast polarography; differential pulse polarography;
D O I
10.1016/j.jpba.2004.04.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polarographic study about how three anti-inflammatories, such as Aceclofenac, Tenoxicam and Droxicam behave, using last polarography (TP) and differential pulse polarography (DPP) was carried out. These studies were always carried out in a media formed by Methanol-Britton-Robinson aqueous buffer (0.1 M) (4:96 (v/v)) due to the low solubility of these drugs in water. A strong influence of pH on analytical signals was observed, showing that the optimal pH values were between 4 and 5. Using DPP in the optimal experimental conditions, a detection limit of 10 ppb for Tenoxicam and Droxicam and 52 ppb for Aceclofenac was reached. The DPP proposed method was successfully applied to the determination of the active compounds in commercial drugs. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 15 条
[1]  
Acuna JA, 1998, QUIM ANAL, V17, P105
[2]   Electrochemical behaviour of droxicam:: kinetic study in aqueous-organic media [J].
Acuña, JA ;
de la Fuente, C ;
Vázquez, MD ;
Tascón, ML ;
Gómez, MI ;
Mata, F ;
Sánchez-Batanero, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (04) :617-624
[3]   A COMPARISON BETWEEN GASTROINTESTINAL BLOOD-LOSS CAUSED BY TILCOTIL (RO 12-0068) AND ASPIRIN IN NORMAL VOLUNTEERS [J].
BIRD, HA ;
BAMFORD, L ;
PICKUP, ME ;
MCEVOY, M ;
GALLOWAY, DB ;
GASGOINE, EW ;
JEUNET, FS ;
WRIGHT, V .
CURRENT MEDICAL RESEARCH AND OPINION, 1982, 8 (01) :9-13
[4]  
BOND MA, 1980, MODERN PALROGRAPHIC
[5]   DETERMINATION OF TENOXICAM, AND THE ISOLATION, IDENTIFICATION AND DETERMINATION OF RO 17-6661, ITS MAJOR METABOLITE, IN HUMAN-URINE [J].
DELL, D ;
JOLY, R ;
MEISTER, W ;
ARNOLD, W ;
PARTOS, C ;
GULDIMANN, B .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :483-492
[6]   RAPID METHOD FOR THE DETERMINATION OF EITHER PIROXICAM OR TENOXICAM IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DIXON, JS ;
LOWE, JR ;
GALLOWAY, DB .
JOURNAL OF CHROMATOGRAPHY, 1984, 310 (02) :455-459
[7]  
FARRE AJ, 1986, METHOD FIND EXP CLIN, V8, P407
[8]   TENOXICAM - A PRELIMINARY REVIEW OF ITS PHARMACODYNAMIC AND PHARMACOKINETIC PROPERTIES, AND THERAPEUTIC EFFICACY [J].
GONZALEZ, JP ;
TODD, PA .
DRUGS, 1987, 34 (03) :289-310
[9]   DETERMINATION OF TENOXICAM IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HEIZMANN, P ;
KORNER, J ;
ZINAPOLD, K .
JOURNAL OF CHROMATOGRAPHY, 1986, 374 (01) :95-102
[10]  
Meits L., 1965, Polarographic techniques, V2