摘要
OBJECTIVE. Our objective was to compare intravascular sonography with digital subtraction angiography (DSA) in the assessment of luminal dimension and morphologic features of endovascular stents and stent grafts. MATERIALS AND METHODS. Thirty-seven pelvic and 24 femoral stents (12 Wallstents: 27 covered and 22 uncovered nitinol stents) in 50 patients were evaluated 15 +/- 10 months after implantation by DSA and intravascular sonography, The degree of maximum in-stent restenosis as revealed by DSA and intravascular sonography was compared for each location, Morphologic features of the stents and stenoses were also assessed. RESULTS, Intravascular sonography and DSA correlated well (R-2 = .96) in determining in-stent restenosis, In-stent restenosis was underestimated by 13% +/- 6% by DSA compared with intravascular sonography. Differences in determining in-stent restenosis with intravascular sonography and DSA were not associated with severity of stenosis or type of stent, Intravascular sonography revealed incomplete expansion of stents in 21 cases, whereas DSA revealed incomplete expansion of stents in seven cases. The intra-and interobserver variabilities in our study were 4% and 5%, respectively. CONCLUSION. In-stent restenoses are underestimated with DSA, Intravascular sonography is superior to DSA for detection of incomplete stent expansion.
引用
收藏
页码:1181 / 1185
页数:5
相关论文
共 23 条
  • [1] Batkoff BW, 1996, CATHETER CARDIO DIAG, V38, P238, DOI 10.1002/(SICI)1097-0304(199607)38:3<238::AID-CCD3>3.0.CO
  • [2] 2-9
  • [3] BENENATI JF, 1995, RADIOL CLIN N AM, V33, P31
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] BOLZ KD, 1995, ACTA RADIOL, V36, P280
  • [6] INTRAVASCULAR ULTRASOUND VERSUS ANGIOGRAPHY FOR MEASUREMENT OD LUMINAL DIAMETERS IN NORMAL AND DISEASED CORONARY-ARTERIES
    DESCHEERDER, I
    DEMAN, F
    HERREGODS, MC
    WILCZEK, K
    BARRIOS, L
    RAYMENANTS, E
    DESMET, W
    DEGEEST, H
    PIESSENS, J
    [J]. AMERICAN HEART JOURNAL, 1994, 127 (02) : 243 - 251
  • [7] INTRAVASCULAR ULTRASONOGRAPHY BEFORE AND AFTER INTERVENTION - IN-VIVO COMPARISON WITH ANGIOGRAPHY
    GERRITSEN, GP
    GUSSENHOVEN, EJ
    THE, SHK
    PIETERMAN, H
    VANDERLUGT, A
    LI, WG
    BOM, N
    VANDIJK, LC
    DUBOIS, NAJJ
    VANURK, H
    [J]. JOURNAL OF VASCULAR SURGERY, 1993, 18 (01) : 31 - 40
  • [8] VESSEL SIZING WIRE - ACCURATE VESSEL MEASUREMENT USING DIGITAL SUBTRACTION ARTERIOGRAPHY
    HALDEN, WJ
    WHITE, RI
    BRIGHT, J
    MITCHELL, SE
    CHANG, R
    [J]. RADIOLOGY, 1986, 161 (02) : 556 - 557
  • [9] MORPHOLOGICAL EFFECTS OF CORONARY BALLOON ANGIOPLASTY INVIVO ASSESSED BY INTRAVASCULAR ULTRASOUND IMAGING
    HONYE, J
    MAHON, DJ
    JAIN, A
    WHITE, CJ
    RAMEE, SR
    WALLIS, JB
    ALZARKA, A
    TOBIS, JM
    [J]. CIRCULATION, 1992, 85 (03) : 1012 - 1025
  • [10] COMBINATION BALLOON-ULTRASOUND IMAGING CATHETER FOR PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY - VALIDATION OF IMAGING, ANALYSIS OF RECOIL, AND IDENTIFICATION OF PLAQUE FRACTURE
    ISNER, JM
    ROSENFIELD, K
    LOSORDO, DW
    ROSE, L
    LANGEVIN, RE
    RAZVI, S
    KOSOWSKY, BD
    [J]. CIRCULATION, 1991, 84 (02) : 739 - 754