Determination of the antidepressant fluoxetine in human plasma by LC with UV detection

被引:38
作者
Maya, MT
Domingos, CR
Guerreiro, MT
Morais, JA
机构
[1] Univ Lisbon, Fac Farm, Ctr Patogenese Mol, P-1600 Lisbon, Portugal
[2] Univ Lisbon, Fac Farm, P-1699 Lisbon, Portugal
关键词
high-performance liquid chromatography (HPLC); quantitative analysis; fluoxetine (FLX);
D O I
10.1016/S0731-7085(00)00367-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective and sensitive isocratic high-performance liquid chromatographic (HPLC) method was developed for the quantitative analysis of low concentrations of fluoxetine (FLX) in human plasma, with ultra-violet detection at 226 nm. A reversed-phase column, LiChrospher((R)) 60 RP-Select B (125 x 3 mm i.d., 5 mum) (Merck), was used to resolve FLX and diazepam (DZP) (internal standard) from endogenous matrix interferences. FLX was isolated from plasma by liquid-liquid extraction. Two identical HPLC systems were used, both validated under the same study conditions. Each chromatographic separation was completed in 30 min and the results showed a mean relative recovery of 101 and 99.3% and an overall precision (RSD%) of 4.78 and 6.09 for each HPLC system. The standard curve was linear for FLX concentrations over the range of 5.00-50.0 ng ml(-1) (R = 0.997 and 0.998).The limit of quantitation of FLX was 5 ng ml(-1) for both HPLC systems. The method described was applied to the analysis of plasma samples obtained from healthy subjects treated with one single oral dose of 40 mg of fluoxetine. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:989 / 996
页数:8
相关论文
共 13 条
  • [1] FLUOXETINE - A REVIEW OF ITS PHARMACODYNAMIC AND PHARMACOKINETIC PROPERTIES, AND THERAPEUTIC EFFICACY IN DEPRESSIVE-ILLNESS
    BENFIELD, P
    HEEL, RC
    LEWIS, SP
    [J]. DRUGS, 1986, 32 (06) : 481 - 508
  • [2] THE SAFETY OF FLUOXETINE - AN UPDATE
    COOPER, GL
    [J]. BRITISH JOURNAL OF PSYCHIATRY, 1988, 153 : 77 - 86
  • [3] SOLID-PHASE EXTRACTION OF FLUOXETINE AND NORFLUOXETINE FROM SERUM WITH GAS-CHROMATOGRAPHY ELECTRON-CAPTURE DETECTION
    DIXIT, V
    NGUYEN, H
    DIXIT, VM
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 563 (02): : 379 - 384
  • [4] SIMULTANEOUS DETERMINATION OF ANTIDEPRESSANT DRUGS AND METABOLITES BY HPLC - DESIGN AND VALIDATION OF A SIMPLE AND RELIABLE ANALYTICAL PROCEDURE
    JORON, S
    ROBERT, H
    [J]. BIOMEDICAL CHROMATOGRAPHY, 1994, 8 (04) : 158 - 164
  • [5] NASH JF, 1982, CLIN CHEM, V28, P2100
  • [6] ORSULAK PJ, 1988, CLIN CHEM, V34, P1875
  • [7] EFFECTIVE TREATMENT OF BULIMIA WITH FLUOXETINE, A SEROTONIN REUPTAKE INHIBITOR, IN A PATIENT WITH TYPE-I DIABETES-MELLITUS
    RAMIREZ, LC
    ROSENSTOCK, J
    STROWIG, S
    CERCONE, S
    RASKIN, P
    [J]. AMERICAN JOURNAL OF MEDICINE, 1990, 88 (05) : 540 - 541
  • [8] ROOSE SP, 1990, PROGR PSYCHIAT, V25, P157
  • [9] FLUOXETINE IN PANIC DISORDER
    SCHNEIER, FR
    LIEBOWITZ, MR
    DAVIES, SO
    FAIRBANKS, J
    HOLLANDER, E
    CAMPEAS, R
    KLEIN, DF
    [J]. JOURNAL OF CLINICAL PSYCHOPHARMACOLOGY, 1990, 10 (02) : 119 - 121
  • [10] SHAH P, 1992, J PHARM SCI, V3, P309