Accuracy and clinical applicability of a passive marker based frameless neuronavigation system

被引:35
作者
Muacevic, A [1 ]
Uhl, E [1 ]
Steiger, HJ [1 ]
Reulen, HJ [1 ]
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Neurosurg, D-81377 Munich, Germany
关键词
computer-aided surgery; neuronavigation; frameless stereotaxy; passive marker systems;
D O I
10.1054/jocn.1999.0226
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
A passive marker system permits the inclusion of an unlimited number of instruments and other devices during frameless stereotaxy. The aim of this study was to evaluate the accuracy and clinical applicability of a passive marker based frameless image guided system (VectorVision; BrainLab, Heimstetten, Germany) developed for surgical planning and intraoperative image guidance. The system was first applied to a plastic phantom to determine the accuracy of the system by measuring the difference between the actual probe position and its analogous position on the monitor screen. The navigational device was subsequently applied to 40 procedures for brain tumours and cavernomas. The mean error value between the image on the monitor screen and the real location in the phantom and the clinical study was 1.45 mm (+/- 0.99) and 4.05 mm (+/- 3.62), respectively. Many different instruments could be employed as pointing devices. It was helpful in minimising the size of the craniotomy. An average lengthening of the surgical procedure of 20 minutes was experienced. The neuronavigation system proved to be a useful surgical tool to approach and detect lesions larger than 5 mm in diameter. The passive marker technology is intuitive and enables the surgeon to use his or her own instruments at any time as a pointing device, thus avoiding further costs for specially designed surgical equipment. (C) 2000 Harcourt Publishers Ltd.
引用
收藏
页码:414 / 418
页数:5
相关论文
共 30 条
[1]   USE OF A FRAMELESS, ARMLESS STEREOTAXIC WAND FOR BRAIN-TUMOR LOCALIZATION WITH 2-DIMENSIONAL AND 3-DIMENSIONAL NEUROIMAGING [J].
BARNETT, GH ;
KORMOS, DW ;
STEINER, CP ;
WEISENBERGER, J .
NEUROSURGERY, 1993, 33 (04) :674-678
[2]   INTRAOPERATIVE LOCALIZATION USING AN ARMLESS, FRAMELESS STEREOTAXIC WAND - TECHNICAL NOTE [J].
BARNETT, GH ;
KORMOS, DW ;
STEINER, CP ;
WEISENBERGER, J .
JOURNAL OF NEUROSURGERY, 1993, 78 (03) :510-514
[3]   Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications [J].
Black, PM ;
Moriarty, T ;
Alexander, E ;
Stieg, P ;
Woodard, EJ ;
Gleason, PL ;
Martin, CH ;
Kikinis, R ;
Schwartz, RB ;
Jolesz, FA .
NEUROSURGERY, 1997, 41 (04) :831-842
[4]  
BUCHOLZ R, 1997, COMP AID SURG
[5]  
BUCHOLZ RD, 1994, INTERACTIVE IMAGE GU, P179
[6]   Postimaging brain distortion: magnitude, correlates, and impact on neuronavigation [J].
Dorward, NL ;
Alberti, O ;
Velani, B ;
Gerritsen, FA ;
Harkness, WFJ ;
Kitchen, ND ;
Thomas, DGT .
JOURNAL OF NEUROSURGERY, 1998, 88 (04) :656-662
[7]   ISC VIEWING WAND SYSTEM [J].
DRAKE, JM ;
RUTKA, JT ;
HOFFMAN, HJ .
NEUROSURGERY, 1994, 34 (06) :1094-1097
[8]  
FAHLBUSCH R, 1997, COMP AID SURG, pS14
[9]  
GALLOWAY R L JR, 1991, Biomedical Instrumentation and Technology, V25, P457
[10]  
GIORGI C, 1997, COMP AID SURG, pS7