MR imaging of sodium in the human brain with a fast three-dimensional gradient-recalled-echo sequence at 4 T

被引:20
作者
Clayton, DB
Lenkinski, RE
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Dept Radiol, Boston, MA 02215 USA
关键词
brain; MR; white matter; magnetic resonance; sodium studies;
D O I
10.1016/S1076-6332(03)80023-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Sodium ions play a vital role in cellular homeostasis and electrochemical activity throughout the human body. However, the in vivo detection of sodium (Na-23) with magnetic resonance (MR) techniques is hindered by the fast transverse relaxation, low tissue equivalent concentration, and small gyromagnetic ratio of sodium ions compared with protons (H-1). The goals of this study were to acquire MR images of sodium in the whole human brain by using a fast three-dimensional gradient-recalled-echo sequence and to investigate the effect that restrictions on specific absorption ratio have on MR imaging of sodium at 4 T. Materials and Methods. A three-dimensional gradient-recalled-echo sequence with short echo time was developed for MR imaging of sodium. Slab encoding was removed and a hard excitation pulse was used. Five healthy human volunteers were examined in a whole-body MR imager with the use of a custom transmit-and-receive birdcage coil. Fields of view were selected to cover the entire brain: 38 X 38 cm in the axial plane, with 24 sections of 5.8 mm each or 12 sections of 1.1 cm each. The in-plane acquisition matrix was 64 X 128, and voxel size was 0.2 cm(3). Results. Sodium in white matter was depicted with an acceptable signal-to-noise ratio of 20-25. The echo time, and hence the signal-to-noise ratio, was limited by the MR imager's maximum allowable gradient strength. To keep the specific absorption ratio below 3 W/kg (the limit established by the Food and Drug Administration), it was necessary to prolong the repetition time to 30 msec. Conclusion. The MR imaging protocol used in this study provided acceptable visualization of sodium in the whole brain in a tolerable total acquisition time of 15 minutes.
引用
收藏
页码:358 / 365
页数:8
相关论文
共 38 条
[1]   OBSERVATION AND GENERAL INTERPRETATION OF SODIUM MAGNETIC-RESONANCE IN BIOLOGICAL-MATERIAL [J].
BERENDSEN, HJ ;
EDZES, HT .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1973, 204 (MAR30) :459-485
[2]   QUANTITATIVE IN-VIVO TISSUE SODIUM CONCENTRATION MAPS - THE EFFECTS OF BIEXPONENTIAL RELAXATION [J].
BOADA, FE ;
CHRISTENSEN, JD ;
HUANGHELLINGER, FR ;
REESE, TG ;
THULBORN, KR .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (02) :219-223
[3]   Fast three dimensional sodium imaging [J].
Boada, FE ;
Gillen, JS ;
Shen, GX ;
Chang, SY ;
Thulborn, KR .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) :706-715
[4]   Spectrally weighted twisted projection imaging: Reducing T-2 signal attenuation effects in fast three-dimensional sodium imaging [J].
Boada, FE ;
Shen, GX ;
Chang, SY ;
Thulborn, KR .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :1022-1028
[5]   SENSITIVITY AND PERFORMANCE TIME IN NMR IMAGING [J].
BRUNNER, P ;
ERNST, RR .
JOURNAL OF MAGNETIC RESONANCE, 1979, 33 (01) :83-106
[7]   INTRACELLULAR SODIUM AND LITHIUM NMR RELAXATION-TIMES IN THE PERFUSED FROG-HEART [J].
BURSTEIN, D ;
FOSSEL, ET .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (03) :261-273
[8]   Quantitative tissue sodium concentration mapping of normal rat brain [J].
Christensen, JD ;
Barrere, BJ ;
Boada, FE ;
Vevea, JM ;
Thulborn, KR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) :83-89
[9]  
CLAYTON DB, 2000, THESIS U PENNSYLVANI
[10]   Steady state effects in fast gradient echo magnetic resonance imaging [J].
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :559-568