Photopolymerized monolithic capillary columns for rapid micro high-performance liquid chromatographic separation of proteins

被引:101
作者
Lee, D
Svec, F
Fréchet, JMJ
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[2] EO Lawrence Berkeley Natl Lab, Div Mat Sci, Berkeley, CA 94720 USA
关键词
monolithic columns; stationary phases; LC proteins;
D O I
10.1016/j.chroma.2004.04.047
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The preparation of monolithic poly(butyl methacrylate-co-ethylene dimethacrylate) capillary columns using photoinitiated in situ polymerization within 200 mum i.d. capillaries and their application for muHPLC separations of proteins have been studied. The low resistance to flow characteristic of monolithic columns, enabled the use of very high flow rates of up to 100 muL/min representing a flow velocity of 87 mm/s. Very good separations of a model protein mixture consisting of ribonuclease A, cytochrome c, myoglobin, and ovalbumin was achieved in less than 40 s using a very simple single step gradient of the mobile phase. Interestingly, no effect of the pore size on the separations of proteins was observed for these monolithic columns within the size range of 0.66-2.2 mum. The monolithic muHPLC columns are found very robust and no changes in the long term separation performance and back pressure were observed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 50 条
[1]   Methacrylate monolithic columns of 320 μm ID for capillary liquid chromatography [J].
Coufal, P ;
Cihák, M ;
Suchánková, J ;
Tesarová, E ;
Bosáková, Z ;
Stulík, K .
JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) :99-106
[2]  
Deyl Z., 2001, Capillary electrochromatography, V1st ed.
[3]   Preparation of continuous beds for electrochromatography and reversed-phase liquid chromatography of low-molecular-mass compounds [J].
Ericson, C ;
Liao, JL ;
Nakazato, K ;
Hjerten, S .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :33-41
[4]  
Hancock WS, 2002, PROTEOMICS, V2, P352, DOI 10.1002/1615-9861(200204)2:4<352::AID-PROT352>3.0.CO
[5]  
2-U
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS [J].
HJERTEN, S ;
LIAO, JL ;
ZHANG, R .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :273-275
[7]   Surface-alkylated polystyrene monolithic columns for peptide analysis in capillary liquid chromatography-electrospray ionization mass spectrometry [J].
Huang, XA ;
Zhang, S ;
Schultz, GA ;
Henion, J .
ANALYTICAL CHEMISTRY, 2002, 74 (10) :2336-2344
[8]   Mutation detection by capillary denaturing high-performance liquid chromatography using monolithic columns [J].
Huber, CG ;
Premstaller, A ;
Wen, X ;
Oberacher, H ;
Bonn, GK ;
Oefner, PJ .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 47 (1-2) :5-19
[9]  
ISHII D, 1988, INTRO MICROSCALE HPL
[10]   Low-attomole electrospray ionization MS and MS/MS analysis of protein tryptic digests using 20-μm-i.d. polystyrene-divinylbenzene monolithic capillary columns [J].
Ivanov, AR ;
Zang, L ;
Karger, BL .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5306-5316