Low-attomole electrospray ionization MS and MS/MS analysis of protein tryptic digests using 20-μm-i.d. polystyrene-divinylbenzene monolithic capillary columns

被引:134
作者
Ivanov, AR
Zang, L
Karger, BL [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
关键词
D O I
10.1021/ac030163g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work explores the use of 20-mum-i.d. polymeric polystyrene-divinylbenzene monolithic nanocapillary columns for the LC-ESI-MS analysis of tryptic digest peptide mixtures. In contrast to the packing of microparticles, capillary columns were prepared, without the need of high pressure, in fused-silica capillaries, by thermally induced in situ copolymerization of styrene and divinylbenzene. The polymerization conditions and mobile-phase composition were optimized for chromatographic performance leading to efficiencies over 100 000 plates/m for peptide separations. High mass sensitivity (similar to10 amol of peptides) in the MS and MS/MS modes using an ion trap MS was found, a factor of up to 20-fold improvement over 75-mum-i.d. nanocolumns. A wide linear dynamic range (similar to4 orders of magnitude) was achieved, and good run-to-run and column-to-column reproducibility of isocratic and gradient elution separations were found. As samples, both model proteins and tissue extracts were employed. Gradient nano-LC-MS analysis of a proteolytic digest of a tissue extract, equivalent to a sample size of similar to1000 cells injected, is presented.
引用
收藏
页码:5306 / 5316
页数:11
相关论文
共 36 条
[1]  
Bente P.F., 1989, U.S. Pat, Patent No. [4,810,456, 4810456]
[2]   Relating electrospray ionization response to nonpolar character of small peptides [J].
Cech, NB ;
Enke, CG .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2717-2723
[3]   Predicting electrospray response from chromatographic retention time [J].
Cech, NB ;
Krone, JR ;
Enke, CG .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :208-213
[4]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[5]  
Enlund AM, 2001, ELECTROPHORESIS, V22, P511, DOI 10.1002/1522-2683(200102)22:3<511::AID-ELPS511>3.0.CO
[6]  
2-W
[7]   ION FORMATION FROM CHARGED DROPLETS - ROLES OF GEOMETRY, ENERGY, AND TIME [J].
FENN, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :524-535
[8]   SMALL-VOLUME AND LOW FLOW-RATE ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF AQUEOUS SAMPLES [J].
GALE, DC ;
SMITH, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (11) :1017-1021
[9]   Characterization of high molecular mass linear polyacrylamide powder prepared by emulsion polymerization as a replaceable polymer matrix for DNA sequencing by capillary electrophoresis [J].
Goetzinger, W ;
Kotler, L ;
Carrilho, E ;
Ruiz-Martinez, MC ;
Salas-Solano, O ;
Karger, BL .
ELECTROPHORESIS, 1998, 19 (02) :242-248
[10]   Capillary LC-MS2 at the attomole level for monitoring and discovering endogenous peptides in microdialysis samples collected in vivo [J].
Haskins, WE ;
Wang, ZQ ;
Watson, CJ ;
Rostand, RR ;
Witowski, SR ;
Powell, DH ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5005-5014