Venous cuff pressures from 30 mmHg to diastolic pressure are recommended to measure arterial inflow by plethysmography

被引:46
作者
Groothuis, JT [1 ]
van Vliet, L [1 ]
Kooijman, M [1 ]
Hopman, MTE [1 ]
机构
[1] UMCN, Dept Physiol, NL-6500 HB Nijmegen, Netherlands
关键词
arterial blood flow; forearm; upper leg; calf; perfusion pressure;
D O I
10.1152/japplphysiol.00022.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Venous occlusion strain gauge plethysmography (VOP) is based on the assumption that the veins are occluded and arterial inflow is undisturbed by the venous cuff pressure. Literature is not clear concerning the pressure that should be used. The purpose of this study was to determine the optimal venous occlusion pressure at which the highest arterial inflow is achieved in the forearm, calf, and leg by using VOP. We hypothesized that, for each limb segment, an optimal ( range of) venous cuff pressure can be determined. Arterial inflow in each limb segment was measured in nine healthy individuals by VOP by using pressures ranging from 10 mmHg up to diastolic blood pressure. Arterial inflows were similar at cuff pressures between 30 and 60 mmHg for the forearm, leg, and calf. Arterial inflow in the forearm was significantly lower at 10 mmHg compared with the other cuff pressures. In addition, arterial inflows at 20 mmHg tended to be lower in each limb segment than flow at higher cuff pressures. In conclusion, no single optimum venous cuff pressure, at which a highest arterial inflow is achieved, exists, but rather a range of optimum cuff pressures leading to a similar arterial inflow. Venous cuff pressures ranging from 30 mmHg up to diastolic blood pressure are recommended to measure arterial inflow by VOP.
引用
收藏
页码:342 / 347
页数:6
相关论文
共 27 条
[1]  
ALTENKIRCH HU, 1990, VASA-J VASCULAR DIS, V19, P21
[2]  
ALTENKIRCH HU, 1989, VASA-J VASCULAR DIS, V18, P140
[3]   Occlusion cuff position is an important determinant of the time course and magnitude of human brachial artery flow-mediated dilation [J].
Berry, KL ;
Skyrme-Jones, RAP ;
Meredith, IT .
CLINICAL SCIENCE, 2000, 99 (04) :261-267
[4]  
BRAKKEE AJM, 1982, VASA-J VASCULAR DIS, V11, P166
[5]   Reproducibility of resting peripheral blood flow using strain gauge plethysmography [J].
Fehling, PC ;
Arciero, PJ ;
MacPherson, CJ ;
Smith, DL .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1999, 20 (08) :555-559
[6]   METHODS FOR INVESTIGATION OF PERIPHERAL BLOOD FLOW [J].
GREENFIELD, ADM ;
WHITNEY, RJ ;
MOWBRAY, JF .
BRITISH MEDICAL BULLETIN, 1963, 19 (02) :101-&
[7]  
Hewlett AW, 1909, HEART-J STUD CIRC, V1, P87
[8]   VENOUS OCCLUSION PLETHYSMOGRAPHY REDUCES ARTERIAL DIAMETER AND FLOW VELOCITY [J].
HIATT, WR ;
HUANG, SY ;
REGENSTEINER, JG ;
MICCO, AJ ;
ISHIMOTO, G ;
MANCOJOHNSON, M ;
DROSE, J ;
REEVES, JT .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (05) :2239-2244
[9]   ELECTRICALLY CALIBRATED PLETHYSMOGRAPH FOR DIRECT MEASUREMENT OF LIMB BLOOD-FLOW [J].
HOKANSON, DE ;
SUMNER, DS ;
STRANDNESS, DE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1975, BM22 (01) :25-29
[10]  
Hopman MT, 1996, ADV EXP MED BIOL, V388, P378