Venous cuff pressures from 30 mmHg to diastolic pressure are recommended to measure arterial inflow by plethysmography

被引:46
作者
Groothuis, JT [1 ]
van Vliet, L [1 ]
Kooijman, M [1 ]
Hopman, MTE [1 ]
机构
[1] UMCN, Dept Physiol, NL-6500 HB Nijmegen, Netherlands
关键词
arterial blood flow; forearm; upper leg; calf; perfusion pressure;
D O I
10.1152/japplphysiol.00022.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Venous occlusion strain gauge plethysmography (VOP) is based on the assumption that the veins are occluded and arterial inflow is undisturbed by the venous cuff pressure. Literature is not clear concerning the pressure that should be used. The purpose of this study was to determine the optimal venous occlusion pressure at which the highest arterial inflow is achieved in the forearm, calf, and leg by using VOP. We hypothesized that, for each limb segment, an optimal ( range of) venous cuff pressure can be determined. Arterial inflow in each limb segment was measured in nine healthy individuals by VOP by using pressures ranging from 10 mmHg up to diastolic blood pressure. Arterial inflows were similar at cuff pressures between 30 and 60 mmHg for the forearm, leg, and calf. Arterial inflow in the forearm was significantly lower at 10 mmHg compared with the other cuff pressures. In addition, arterial inflows at 20 mmHg tended to be lower in each limb segment than flow at higher cuff pressures. In conclusion, no single optimum venous cuff pressure, at which a highest arterial inflow is achieved, exists, but rather a range of optimum cuff pressures leading to a similar arterial inflow. Venous cuff pressures ranging from 30 mmHg up to diastolic blood pressure are recommended to measure arterial inflow by VOP.
引用
收藏
页码:342 / 347
页数:6
相关论文
共 27 条
[11]   Increased vascular resistance in paralyzed legs after spinal cord injury is reversible by training [J].
Hopman, MTE ;
Groothuis, JT ;
Flendrie, M ;
Gerrits, KHL ;
Houtman, S .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (06) :1966-1972
[12]   From Belfast to Mayo and beyond: the use and future of plethysmography to study blood flow in human limbs [J].
Joyner, MJ ;
Dietz, NM ;
Shepherd, JT .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (06) :2431-2441
[13]   ROLE OF THE WRIST CUFF IN FOREARM PLETHYSMOGRAPHY [J].
LENDERS, J ;
JANSSEN, GJ ;
SMITS, P ;
THIEN, T .
CLINICAL SCIENCE, 1991, 80 (05) :413-417
[14]  
LORENTSEN E, 1970, ANGIOLOGY, V21, P661
[15]   STRAIN-GAUGE PLETHYSMOGRAPHY AND DOPPLER ULTRASOUND IN THE MEASUREMENT OF LIMB BLOOD-FLOW [J].
PALLARES, LCM ;
DEANE, CR ;
BAUDOUIN, SV ;
EVANS, TW .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1994, 24 (04) :279-286
[16]  
PEDRINELLI R, 1987, J HYPERTENS S5, V5, pS431
[17]   VENOUS PLETHYSMOGRAPHY - MEASURING TECHNIQUES AND NORMAL VALUES [J].
POINTEL, JP ;
GIN, H ;
DROUIN, P ;
VERNHES, G ;
DEBRY, G .
ANGIOLOGY, 1981, 32 (03) :145-154
[18]   INFLUENCE OF SEX AND BODY-WEIGHT ON FOREARM HEMODYNAMICS IN PATIENTS WITH SUSTAINED ESSENTIAL-HYPERTENSION [J].
RAISON, JH ;
SAFAR, ME ;
LONDON, GM .
AMERICAN JOURNAL OF HYPERTENSION, 1991, 4 (10) :820-826
[19]   THE REPRODUCIBILITY OF LIMB BLOOD-FLOW MEASUREMENTS IN HUMAN VOLUNTEERS AT REST AND AFTER EXERCISE BY USING MERCURY-IN-SILASTIC STRAIN-GAUGE PLETHYSMOGRAPHY UNDER STANDARDIZED CONDITIONS [J].
ROBERTS, DH ;
TSAO, Y ;
BRECKENRIDGE, AM .
CLINICAL SCIENCE, 1986, 70 (06) :635-638
[20]   The diameter of the common femoral artery in healthy human:: Influence of sex, age, and body size [J].
Sandgren, T ;
Sonesson, B ;
Ahlgren, ÅR ;
Länne, T .
JOURNAL OF VASCULAR SURGERY, 1999, 29 (03) :503-510